NIIN Output Data
NIIN:
NSN:
Item Name:
SOLENOID , ELECTRICAL
Definition:
AN ITEM CONSISTING OF ONE OR MORE COILS SURROUNDING AN IRON CORE. THE COIL(S) AND THE CORE ARE MOVEABLE IN RELATION TO EACH OTHER. THE AXIAL OR ROTARY MOVEMENT IS A RESULT OF THE MAGNETIC FLUX OF THE COIL. IT IS DESIGNED TO CONVERT ELECTRICAL ENERGY INTO MECHANICAL ENERGY. IT DOES NOT INCLUDE SWITCH CONTACTS. SEE ALSO RELAY, ELECTROMAGNETIC, AND ELECTROMAGNETIC ACTUATOR.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
L2424 | 81983 | A | 5 | 2 | 1 | TX | ||
HP84500 | 57817 | R | 5 | 9 | 5 | TX | ||
E-38200 | 34802 | A | 5 | 2 | 5 | ZZ | ||
HP848500 | 70236 | A | 3 | 2 | 5 | ZZ | ||
HP848500 | 84685 | H | 5 | 9 | 1 | TX | ||
CC8548 | 72154 | F | 5 | 9 | 1 | TX | ||
5436 | 07797 | A | 5 | 2 | 1 | TX |
CAGE Information
Code | Company |
---|---|
07797 | ROCKER SOLENOID COMPANY DBA ROCKER I |
81983 | G.W. LISK COMPANY INC. |
57817 | TACTAIR FLUID CONTROLS INC PHOENIX C |
34802 | ELECTROMOTIVE INC |
70236 | TACTAIR FLUID CONTROLS INC. |
84685 | TELEDYNE HYDRA-POWER DIV OF TELEDYNE |
72154 | COLONIAL ELECTRICAL CO INC |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CNXW | LINEAR FORCE DELIVERED | 4.50 POUNDS |
CNXW | LINEAR FORCE DELIVERED | 4.50 POUNDS |
ADAQ | BODY LENGTH | 1.188 INCHES NOMINAL |
ABPM | BODY DIAMETER | 0.875 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 TERMINAL |
CNXX | POWER TAKEOFF CONNECTION TYPE | INTERNAL PLUNGER |
APAF | MAGNETIC COIL QUANTITY | 1 |
ASXH | VOLTAGE RATING IN VOLTS | 30.0 DC MAXIMUM |
ADTV | CASE MATERIAL | ALUMINUM |
APCC | ELECTRICAL RESISTANCE | 40.00 OHMS MINIMUM AND 44.00 OHMS MAXIMUM |
CNYD | ENERGIZING STROKE MAXIMUM LENGTH | 0.015 INCHES |
AEHZ | MAXIMUM OPERATING TEMP | 275.0 DEG FAHRENHEIT |
APNP | DUTY TYPE | CONTINUOUS |
AAQL | BODY STYLE | CYLINDRICAL FRAME |
APXH | TERMINAL LOCATION | ACTUATOR END |
ADZC | ENVIRONMENTAL PROTECTION | HUMIDITY PROOF |
CNXT | ACTUATOR STROKE TYPE | PULL |