NIIN Output Data
NIIN:
NSN:
Item Name:
RELAY , THERMAL
Definition:
A RELAY SWITCH WHICH IS ACTUATED BY THE EFFECT OF INTERNAL HEAT GENERATED BY THE CURRENT IN ITS ENERGIZING CIRCUIT. FOR ITEMS ACTUATED BY AMBIENT, RATHER THAN INTERNAL TEMPERATURE CHANGES, SEE SWITCH, THERMOSTATIC.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
DT-5073 | 93929 | A | 3 | 2 | 3 | TX | ||
DT7053 | 93929 | A | 5 | 9 | 3 | TX |
CAGE Information
Code | Company |
---|---|
93929 | SPX CORPORATION DBA RADIODETECTION |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CYCW | DELAY TIME IN SECONDS | 60.0 FIXED OPERATE NOMINAL |
CYCW | DELAY TIME IN SECONDS | 60.0 FIXED OPERATE NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
CYCS | CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 250.0 AC AND 32.0 DC |
ABHP | OVERALL LENGTH | 2.750 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN |
ADAV | OVERALL DIAMETER | 1.282 INCHES NOMINAL |
APFR | CONTACT ARRANGEMENT | SINGLE POLE, SINGLE THROW, NORMALLY OPEN |
CYCU | HEATER VOLTAGE RATING IN VOLTS | 115.0 |
CYCT | CONTACT MAXIMUM CURRENT RATING IN AMPS | 3.0 AC OR 1.0 DC |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 OCTAL BASE PLUG-IN |