NIIN Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
SMC451463 | 80063 | A | 3 | 2 | 1 | TX | ||
3400127 | 93346 | A | 5 | 9 | 5 | TX | ||
PA33702 | 90095 | A | 5 | 9 | 6 | TX |
CAGE Information
Code | Company |
---|---|
80063 | US ARMY COMMUNICATIONS & ELECTRONICS |
93346 | SENSOR AND ANTENNA SYSTEMS, LANSDALE |
90095 | PULSE ELECTRONICS DBA PULSE COMPONEN |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CRMJ | WINDING POWER RATING | 70.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 70.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 350.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 200.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 155.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKW | OVERALL HEIGHT | 3.440 INCHES NOMINAL |
CRMJ | WINDING POWER RATING | 28.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
ADAU | BODY HEIGHT | 3.060 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 8 SOLDER STUD |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.440 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CRBZ | WINDING OPERATING CURRENT | 80.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
CRMJ | WINDING POWER RATING | 31.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
ADAQ | BODY LENGTH | 2.620 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.000 INCHES NOMINAL |
CWJS | WINDING OPERATING VOLTAGE | 85.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
AAJD | THREAD CLASS (NON-CORE) | 2A SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 35.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |