NIIN Output Data
NIIN:
NSN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
IC5181C102C6AA | 02989 | A | 3 | 2 | X | XX | ||
609867PC6 | 53711 | A | C | 1 | 6 | ZZ | AC |
CAGE Information
Code | Company |
---|---|
02989 | GENERAL ELECTRIC CO GE DRIVE SYSTEMS |
53711 | NAVAL SEA SYSTEMS COMMAND |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
AKDX | WINDING QUANTITY | 1 |
TTQY | TERMINAL TYPE AND QUANTITY | 20 PIN ALL FUNCTIONS |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 45.0 AMPERES AC INDUCTIVE LOAD |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABMK | OVERALL WIDTH | 6.120 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 2 TWO CIRCUIT, BOTH POSITIONS MAINTAINED |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
APCN | COIL QUANTITY | 1 |
ABKW | OVERALL HEIGHT | 6.120 INCHES NOMINAL |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 440.0 VOLTS -80 DEG FAHRENHEIT TYPE 4F SINGLE WINDING |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 5 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
APNP | DUTY TYPE | CONTINUOUS |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 150.0 MILLIAMPERES AC SINGLE WINDING |
CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 440.0 AC AND 230.0 DC |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.406 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ZZZV | FSC APPLICATION DATA (NON-CORE) | EXCEPT ENGINE |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 440.0 AC |
ABHP | OVERALL LENGTH | 6.310 INCHES NOMINAL |
APNA | WINDING DC RESISTANCE RATING | 113.0 OHMS NOMINAL SINGLE WINDING |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |