NIIN Output Data
Definition:
A RESISTOR IN WHICH A SLIDING OR ROLLING CONTACT MOVES OVER AN EXPOSED AREA OF THE RESISTIVE ELEMENT TO CHANGE THE OHMIC VALUE OF THE OUTPUT. THE FUNCTIONAL TOLERANCE (LINEARITY), IF GIVEN, OF THE OUTPUT IS GREATER THAN PLUS OR MINUS 1 PERCENT ON LINEAR OUTPUTS. SPECIFIED OUTPUTS SUCH AS SINE, COSINE, TANGENT, ETC., SHALL BE CONSIDERED TO BE PRECISION. FOR ITEMS HAVING MANUALLY POSITIONED TAPS DESIGNED TO BE SET AND FIXED PRIOR TO USE, SEE RESISTOR, ADJUSTABLE. FOR ITEMS WITH STEP BY STEP VARIATION, SEE RHEOSTAT AND RESISTOR, STEP BY STEP. FOR TANDEM-MOUNTED ITEMS DESIGNED TO FUNCTION TOGETHER AS AN ATTENUATOR (AND RATED ACCORDINGLY), SEE ATTENUATOR, VARIABLE. EXCLUDES RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; AND RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
PM3200RMV | 21066 | R | C | 1 | 6 | ZZ | AC | |
62PR200 | 73138 | A | 5 | 2 | 3 | TX | ||
RS0698017 | D0894 | A | 5 | 2 | 3 | ZG | ||
61PR200 | 73138 | A | C | 1 | 6 | ZZ | AC | |
62PR200 | 80740 | A | C | 1 | 5 | ZZ | AC | |
82PR200 | 73138 | A | 5 | 1 | 3 | TX | ||
R2394 | 06811 | A | 5 | 2 | 5 | KE | ||
29-0131-06 | 04423 | A | C | 1 | 4 | 48 | AH | |
3329H-1-201 | 80294 | A | 5 | 1 | 3 | TX | ||
C3616 | 98869 | A | 5 | 2 | 5 | TX | ||
3450370-5 | 93346 | A | C | 1 | 6 | ZZ | AC | |
11131-0005 | 27914 | A | 5 | 2 | 5 | TU | ||
2100-2061 | 1LQK8 | A | 3 | 2 | 5 | ZZ | ||
62-1-1-200 OHM | 02111 | A | 5 | 2 | 5 | TX | ||
7558001P005 | 94117 | A | 5 | 2 | 5 | TX | ||
62PR200OHM | 73138 | A | 5 | 1 | 3 | TX | ||
845810-0182 | 55819 | F | C | 1 | 5 | 48 | ||
170-200 | 84048 | A | C | 1 | 6 | ZZ | AC | |
2100-2061 | 28480 | A | 5 | 9 | 1 | TX | ||
170-2000HMS-PM20 | 84048 | A | C | 1 | 6 | ZZ | AC | |
170-200 OHM | 84048 | A | 5 | 2 | 5 | TX | ||
60304 | 19905 | H | C | 1 | 6 | ZZ | AC | |
62-1-1-200 OHM | C7407 | H | 5 | 9 | 3 | ZG |
CAGE Information
Code | Company |
---|---|
02111 | VISHAY THIN FILM LLC DBA VISHAY SPEC |
21066 | WAYNE KERR ELECTRONICS INC |
73138 | BI TECHNOLOGIES CORPORATION |
D0894 | ROHDE & SCHWARZ GMBH & CO. KG |
80740 | BECKMAN COULTER INC. DIV NORTH AMERC |
06811 | BEI SENSORS & SYSTEMS COMPANY INC. D |
04423 | TELONIC BERKELEY INC. |
80294 | BOURNS INSTRUMENTS INC |
98869 | HOWELL INSTRUMENTS INC. |
93346 | SENSOR AND ANTENNA SYSTEMS, LANSDALE |
27914 | HONEYWELL INTERNATIONAL INC DBA HONE |
1LQK8 | AGILENT TECHNOLOGIES INC. DIV AGILEN |
94117 | BAE SYSTEMS INFORMATION AND ELECTRON |
55819 | DIAMOND ELECTRONICS INC |
84048 | VERNITRON CORP VRN INTERNATIONAL DIV |
28480 | HEWLETT PACKARD CO |
19905 | APPLIED COMMUNICATIONS A DIV OF AMST |
C7407 | IV-ELECTRONIC KLAUS VESPERMANN KG |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAPN | SECTION QUANTITY | 1 |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
AXGY | MOUNTING METHOD | TERMINAL |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -30.0/+30.0 SINGLE SECTION |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 215.0 NOMINAL |
ABJT | TERMINAL LENGTH | 0.312 INCHES NOMINAL |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 200.0 OHMS SINGLE SECTION |
AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE |
ABPM | BODY DIAMETER | 0.250 INCHES NOMINAL |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.100 INCHES NOMINAL |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 125.0 SINGLE SECTION |
AAQL | BODY STYLE | CYLINDRICAL |
APXH | TERMINAL LOCATION | REAR END |
ADAQ | BODY LENGTH | 0.250 INCHES NOMINAL |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 70.0 SINGLE SECTION |
CSDL | STANDARD TAPER CURVE PER SECTION | A SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR SINGLE SECTION |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0/+100.0 SINGLE SECTION |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 215.0 NOMINAL |