NIIN Output Data
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
812-2202-16 | 83330 | A | 5 | 9 | 4 | CX | ||
812-GP-2202-16 | 26405 | A | 3 | 2 | 4 | CX | ||
64A92C815-6 | 10001 | A | 5 | 2 | 5 | CX |
CAGE Information
Code | Company |
---|---|
10001 | NAVAIR AND NAVSEA MANAGED ORIGINAL D |
83330 | DIALIGHT CORPORATION |
26405 | MARATHON SPECIAL PRODUCTS CORPORATIO |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.719 INCHES |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.719 INCHES |
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
ABGQ | BOARD OVERALL HEIGHT | 0.906 INCHES |
ABGP | BOARD OVERALL WIDTH | 0.750 INCHES |
ABCS | TERMINAL ROW QUANTITY | 1 |
AMPS | CURRENT RATING IN AMPS | 30.0 |
CWLN | TERMINAL DESIGN | NONFEEDTHRU |
CWLG | TERMINAL PATTERN ARRANGEMENT | SINGLE ROW |
MATT | MATERIAL | COPPER ALLOY TERMINALS |
ABGS | BASE THICKNESS | 0.406 INCHES |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 1600.0 |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.563 INCHES |
CRNL | NONFEEDTHRU TERMINAL TYPE | 597 SINGLE |
FEAT | SPECIAL FEATURES | INCL HEX NUTS FOR TERMINALS |
SFTT | SURFACE TREATMENT | NICKEL TERMINALS |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 16 SINGLE |
MATT | MATERIAL | PLASTIC PHENOLIC BOARD |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 9.563 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.203 INCHES |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.375 INCHES |
AAMA | MOUNTING HOLE DIAMETER | 0.209 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
ABGN | BOARD OVERALL LENGTH | 9.969 INCHES |
AAQL | BODY STYLE | BARRIER TYPE |