NIIN Output Data
Definition:
AN ITEM GENERALLY CONSISTING OF ONE OR MORE TURNS OF WIRE OR SIMILAR CONDUCTIVE MATERIAL (IN SPECIAL CASES IT MAY BE CONSIDERED AS A PARTIAL TURN). IT IS SPECIFICALLY DESIGNED TO CONCENTRATE MAGNETIC FLUX GENERATED BY THE FLOW OF AN ELECTRIC CURRENT, TO INDUCE IN ITSELF AN ELECTROMOTIVE FORCE, AND TO ADD OR SUBTRACT INDUCTIVE REACTANCE IN A CIRCUIT. IT MAY INCLUDE TUNING DEVICES, INTEGRAL RESISTORS AND CAPACITORS; HOWEVER, EXCLUDES FILTER (AS MODIFIED). FOR COILS WOUND ON RESISTORS WHICH ARE DESIGNED TO BE INSERTED INTO THE CIRCUIT OF A RADIO FREQUENCY STAGE TO SUPPRESS HIGH FREQUENCY PARASITIC OSCILLATIONS, SEE SUPPRESSOR, PARASITIC..
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
K2051 | 96474 | A | 3 | 2 | 5 | TX | ||
21-157 | 82450 | A | 5 | 2 | 6 | 48 |
CAGE Information
Code | Company |
---|---|
82450 | DETROIT COIL COMPANY |
96474 | GE ZENITH CONTROLS |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABTB | MOUNTING HOLE DIAMETER | 0.266 INCHES NOMINAL SINGLE GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.266 INCHES NOMINAL SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
AKDX | WINDING QUANTITY | 1 SINGLE COMPONENT |
CRGS | DC RESISTANCE RATING IN OHMS | 5.200 SINGLE COMPONENT SINGLE WINDING |
ABHP | OVERALL LENGTH | 2.500 INCHES NOMINAL |
ABHY | TURN QUANTITY | 500 SINGLE COMPONENT SINGLE WINDING |
ABKW | OVERALL HEIGHT | 1.500 INCHES NOMINAL |
CQPZ | WINDING CONDUCTOR SIZE | 0.02846 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE WINDING |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CRBZ | WINDING OPERATING CURRENT | 600.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE WINDING |
AKPV | MOUNTING FACILITY QUANTITY | 4 1ST GROUP |
AKNA | INCLOSURE TYPE | OPEN |
ABMK | OVERALL WIDTH | 2.000 INCHES NOMINAL |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING AND WINDING TURNS SINGLE COMPONENT SINGLE WINDING |