Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
93568 HARSCO CORP BMY-COMBAT SYSTEMS DIV

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
FEAT SPECIAL FEATURES VOLTAGE SENSING 3 PHASE RELAY
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 8.250 INCHES NOMINAL SINGLE MOUNTING FACILITY
APCN COIL QUANTITY 3
ABTD MOUNTING SLOT WIDTH 0.250 INCHES NOMINAL SINGLE MOUNTING FACILITY
AJSS FREQUENCY IN HERTZ 50.0 MINIMUM AND 60.0 MAXIMUM
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 120.0 VOLTS -80 DEG FAHRENHEIT TYPE 4F ALL WINDINGS
TTQY TERMINAL TYPE AND QUANTITY 12 SCREW ALL FUNCTIONS
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 120.0 AC AND 28.0 DC
AKDX WINDING QUANTITY 3
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 SLOTTED HOLE SINGLE MOUNTING FACILITY
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY
APNP DUTY TYPE CONTINUOUS
ABMK OVERALL WIDTH 6.250 INCHES NOMINAL
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 5.0 AMPERES AC RESISTIVE LOAD AND 5.0 AMPERES DC RESISTIVE LOAD
ABKW OVERALL HEIGHT 3.470 INCHES NOMINAL
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 3 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED
ABHP OVERALL LENGTH 8.750 INCHES NOMINAL
CQYJ MOUNTING FACILITY PATTERN RECTANGULAR SINGLE MOUNTING FACILITY

Similar Parts

00154-0660 , 001540660 , 5945-00-500-7612 , 5945005007612 , 005007612