NIIN Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
SAFA03 | 11850 | F | 5 | 9 | 5 | TX | ||
10236493 | 18876 | A | 3 | 2 | 1 | TX |
CAGE Information
Code | Company |
---|---|
11850 | MAGNETIKA/EAST LTD TITAN TRANSFORMER |
18876 | U S ARMY AVIATION AND MISSILE COMMAN |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AAJD | THREAD CLASS (NON-CORE) | 2B SINGLE GROUP |
ACZB | FREQUENCY RATING | 5.0 KILOHERTZ MINIMUM SINGLE COMPONENT AND 6.0 KILOHERTZ MAXIMUM SINGLE COMPONENT |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CWJS | WINDING OPERATING VOLTAGE | 58.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
ADAT | BODY WIDTH | 2.060 INCHES NOMINAL |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.671 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.703 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ADAU | BODY HEIGHT | 3.120 INCHES NOMINAL |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 7.5 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT SINGLE SECONDARY |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 10.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 6 THREADED STUD |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.421 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.453 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ADAQ | BODY LENGTH | 2.310 INCHES NOMINAL |