Follow Us on Google+

Request A Price Quote:

NIIN Output Data

NIIN:
NSN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
AP13-288-32 81541 A 5 9 5 TX
840069-5-32 80249 A 5 9 5 TX
SM-D-586266-2 80063 A 3 2 1 TX
AP13-1874-2 81541 A 5 2 5 TX

CAGE Information

Code Company
80063 US ARMY COMMUNICATIONS & ELECTRONICS
81541 SENSATA TECHNOLOGIES MARYLAND INC
80249 BAE SYSTEMS INFORMATION AND ELECTRON

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
FREQ FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
FREQ FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 20.0 AMPERES AC ALL LOCATIONS
AKPX POLE QUANTITY 2
THSD THREAD SERIES DESIGNATOR UNEF
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 300.0 AC ALL LOCATIONS
TTQY TERMINAL TYPE AND QUANTITY 5 WIRE HOOK
CPRX ACTUATOR POSITION DESIGNATION BETWEEN POLE ONE AND TWO
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.780 INCHES MAXIMUM
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CQJX NOMINAL THREAD SIZE 0.375 INCHES
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP W/AUXILIARY LOAD TERMINAL ALL LOCATIONS
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.500 MINIMUM AT 200 PCT ALL LOCATIONS AND 9.000 MAXIMUM AT 200 PCT ALL LOCATIONS
CPRQ RESET METHOD MANUAL
ABXD BUSHING LENGTH 0.375 INCHES MAXIMUM
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.875 INCHES NOMINAL
CPRJ TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
CPRW ACTUATOR FUNCTION TRIP-RESET
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED HERMETICALLY SEALED
ADAQ BODY LENGTH 1.500 INCHES MAXIMUM
ADTV CASE MATERIAL METAL
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 120.0 AC ALL LOCATIONS
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.625 INCHES NOMINAL
ADAT BODY WIDTH 1.250 INCHES MAXIMUM
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING W/PANEL SEAL
AAQL BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
CMLP THREAD QUANTITY PER INCH 32
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 115.0 ALL LOCATIONS

Similar Parts

SM-D-586266-2 , SMD5862662 , 5925-00-163-3953 , 5925001633953 , 001633953 , AP13-288-32 , 840069-5-32 , SM-D-586266-2 , AP13-1874-2 ,