NIIN Output Data
NIIN:
NSN:
Item Name:
SWITCH , PRESSURE
Definition:
A SWITCH WHICH IS ACTUATED BY CHANGES IN PRESSURE OF ANY GAS OR LIQUID OR BY CHANGES IN A VACUUM ACTING UPON ITS SENSING ELEMENT. EXCLUDES BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; AND SWITCH, SENSITIVE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
266-8397-030 | 13499 | A | 3 | 2 | A | TX | ||
FR26-191857-00 | 85274 | A | 5 | 2 | 5 | TX | ||
W26191857-00 | 85274 | A | C | 1 | 6 | ZZ | AC | |
266-8397-030 | 95105 | A | 5 | 2 | 5 | TX |
CAGE Information
Code | Company |
---|---|
13499 | ROCKWELL COLLINS INC. DBA GOVERNMENT |
85274 | DWYER INSTRUMENTS INC DIV DWYER INST |
95105 | ROCKWELL COLLINS INC. DIV GOVERNMENT |
Federal Supply Class
Title
SWITCHES
Inclusions:
INCLUDES ROTARY, KNIFE, TOGGLE, PUSH BUTTON, MERCURY, THERMOSTATIC, AND DIFFERENTIAL PRESSURE SWITCHES.
Exclusions:
EXCLUDES SWITCHGEAR.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CTZL | PRESSURE CONNECTOR TYPE | PLAIN, THREADED INTERNAL ALL CONNECTIONS |
CTZL | PRESSURE CONNECTOR TYPE | PLAIN, THREADED INTERNAL ALL CONNECTIONS |
AWTN | OPERATING TEMP RATING | -54.0 DEG CELSIUS MINIMUM AND 55.0 DEG CELSIUS MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.125 INCHES ALL PRESSURE CONNECTION |
ABMK | OVERALL WIDTH | 4.594 INCHES MINIMUM AND 4.656 INCHES MAXIMUM |
CTHF | CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CQJB | PROOF PRESSURE | 5.00 POUNDS PER SQUARE INCH |
CSCF | TERMINAL TYPE | SCREW |
CTYM | CONTACT ADJUSTMENT RANGE | +1.40/+5.00 ACTUATION POINT INCHES OF WATER |
AARX | INSIDE DIAMETER | 0.125 INCHES NOMINAL ALL CONNECTIONS |
ABHP | OVERALL LENGTH | 1.812 INCHES MAXIMUM |
AXGY | MOUNTING METHOD | FLANGE AND UNTHREADED HOLE |
CTHF | CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
ADAQ | BODY LENGTH | 1.812 INCHES MAXIMUM |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
ABPM | BODY DIAMETER | 3.500 INCHES NOMINAL |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT POINTER |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.219 INCHES NOMINAL |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 4.219 INCHES MINIMUM AND 4.281 INCHES MAXIMUM |
STYL | STYLE DESIGNATOR | CYLINDRICAL W/MOUNTING LUGS |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 240.0 AC AT SEA LEVEL SECOND VOLTAGE |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
AJZC | PRESSURE SWITCH TYPE | DIFFERENTIAL |
THSD | THREAD SERIES DESIGNATOR | NPT ALL PRESSURE CONNECTION |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL FIRST VOLTAGE |