Follow Us on Google+

Request A Price Quote:

NIIN Output Data

NIIN:
NSN:
Item Name:
RESISTOR , THERMAL

Definition:

A THERMALLY SENSITIVE RESISTOR WHOSE PRIMARY FUNCTION IS TO EXHIBIT A CHANGE IN ELECTRICAL RESISTANCE WITH A CHANGE IN BODY TEMPERATURE. ITEM MAY BE MOUNTED IN A PROBE OR HOUSING. FOR BALLAST TUBE TYPE RESISTORS, SEE RESISTOR (1), CURRENT REGULATING. EXCLUDES TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE AND TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
D168392 64959 R 5 9 X XX
19MS715-2 1MY97 A 3 2 5 ZZ
227898 56232 A 5 9 X XX
P320A60 73760 A 3 2 X XX
19MS715-2 28480 A 5 9 X XX
D168392 70408 F 5 9 5 9Z
B851648 98738 E 3 2 X XX
RTD4 21900 H 5 9 X XX

CAGE Information

Code Company
1MY97 AGILENT TECHNOLOGIES INC. DIV AGILEN
64959 AMERICAN TELEPHONE AND TELEGRAPH CO
56232 LOCKHEED MARTIN CORPORATION DBA LOCK
73760 ITT CORPORATION DBA ITT AREOSPACE CO
28480 HEWLETT PACKARD CO
70408 AT AND T CORP
98738 HERLEY CHICAGO DBA STEWART WARNER EL
21900 FEDERAL DIV OF VICTOREEN INSTRUMENT

Federal Supply Class

Title

RESISTORS

Inclusions:

INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.

Exclusions:

EXCLUDES RESISTANCE WIRE.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
STYL STYLE DESIGNATOR DISK ON SURFACE PLATE
STYL STYLE DESIGNATOR DISK ON SURFACE PLATE
AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 75.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT
TTQY TERMINAL TYPE AND QUANTITY 1 WIRE LEAD
AEJF RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -8.9/+8.9 8TH RESISTANCE-TEMPERATURE POINT
ABJT TERMINAL LENGTH 3.750 INCHES MINIMUM
AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 116.0 OHMS 7TH RESISTANCE-TEMPERATURE POINT
AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 58.0 OHMS 8TH RESISTANCE-TEMPERATURE POINT
AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 0.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
ABKW OVERALL HEIGHT 0.313 INCHES NOMINAL
AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 2.465 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT
AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 725.0 OHMS 5TH RESISTANCE-TEMPERATURE POINT
AEJF RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -9.0/+9.0 2ND RESISTANCE-TEMPERATURE POINT
AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 25.375 OHMS 9TH RESISTANCE-TEMPERATURE POINT
AEJN DISTANCE BETWEEN MOUNTING FACILITY CENTERS 1.000 INCHES NOMINAL
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.0624 INCHES NOMINAL
AARG RELIABILITY INDICATOR NOT ESTABLISHED
AEJF RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -11.0/+11.0 1ST RESISTANCE-TEMPERATURE POINT
AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER -50.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
AEHY AMBIENT TEMP AT FULL RATED POWER 25.0 DEG CELSIUS
AKNA INCLOSURE TYPE ENCAPSULATED
AEJB POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS 150.0
AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 46.4 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT
AEJF RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -7.0/+7.0 4TH RESISTANCE-TEMPERATURE POINT
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 0.6874 INCHES NOMINAL
ABDN TERMINAL SURFACE TREATMENT SOLDER
AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 150.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT
AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 239.25 OHMS 6TH RESISTANCE-TEMPERATURE POINT
AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 100.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT
AEJF RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -5.0/+5.0 5TH RESISTANCE-TEMPERATURE POINT
ABMK OVERALL WIDTH 0.875 INCHES NOMINAL
AEJF RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -7.0/+7.0 6TH RESISTANCE-TEMPERATURE POINT
AEJF RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -12.1/+12.1 10TH RESISTANCE-TEMPERATURE POINT
AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER -10.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 25.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
AEJA THERMAL TIME CONSTANT IN SECONDS 80.0
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.1285 INCHES NOMINAL
AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 50.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT
AEJF RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -8.4/+8.4 3RD RESISTANCE-TEMPERATURE POINT
CBME CUBIC MEASURE 0.342 CUBIC INCHES
AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 13.05 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT
AEJC ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS 4.40
AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 3.045 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT
AEHZ MAXIMUM OPERATING TEMP 150.0 DEG CELSIUS
AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 125.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT
AEJF RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -8.6/+8.6 7TH RESISTANCE-TEMPERATURE POINT
CQWD ZERO POWER RESISTANCE 725.000 OHMS
AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER -30.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 13.05 OHMS 10TH RESISTANCE-TEMPERATURE POINT
AEJF RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -10.0/+10.0 9TH RESISTANCE-TEMPERATURE POINT
ABHP OVERALL LENGTH 1.250 INCHES NOMINAL
AEBT TERMINAL DIAMETER 0.025 INCHES NOMINAL
CRQJ ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP -5.0/+5.0
CTGT REFERENCE TEMP IN DEG CELSIUS 25.0

Similar Parts

19MS715-2 , 19MS7152 , 5905-00-175-5447 , 5905001755447 , 001755447 , D168392 , 19MS715-2 , 227898 , P320A60 , 19MS715-2 , D168392 , B851648 , RTD4 ,