NIIN Output Data
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
K882449-1 | 49671 | F | 5 | 9 | 5 | ZZ | ||
K882449-1 | 21921 | F | 3 | 9 | X | XX |
CAGE Information
Code | Company |
---|---|
21921 | RCA CORP DISTRIBUTOR AND SPECIAL PRO |
49671 | LOCKHEED MARTIN CORP LOCKHEED MARTIN |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
MATT | MATERIAL | PLASTIC BOARD |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.375 INCHES |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.438 INCHES |
ABCS | TERMINAL ROW QUANTITY | 2 |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.500 INCHES |
AAQL | BODY STYLE | BLOCK TYPE |
ABGP | BOARD OVERALL WIDTH | 1.688 INCHES |
ABGQ | BOARD OVERALL HEIGHT | 0.250 INCHES |
CWLG | TERMINAL PATTERN ARRANGEMENT | RANDOM |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.938 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.375 INCHES |
MARK | SPECIAL MARKINGS | 1 THRU 9 |
AAMA | MOUNTING HOLE DIAMETER | 0.199 INCHES |
ABDB | TERMINAL FACILITY QUANTITY | 9 |
ABGN | BOARD OVERALL LENGTH | 4.125 INCHES |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.375 INCHES |