NIIN Output Data
Definition:
AN ENCLOSURE WHICH INCLUDES, MOUNTS, AND PROTECTS ONE OR MORE FUSEHOLDER. IT IS DESIGNED FOR AND MAY INCLUDE A COVER. MAY ALSO INCLUDE ELECTRICAL FUSES, MOUNTING HARDWARE, LOCK(S), CONDUIT FITTINGS, AND TERMINAL BOARD(S) USED SPECIFICALLY FOR TERMINATING THE FUSES OR FUSEHOLDERS. FOR BOXES CONTAINING COMBINATIONS OF DIFFERENT ELECTRICAL DEVICES, SUCH AS SWITCHES, JACKS, FUSEHOLDERS, CONNECTORS, CIRCUIT BREAKERS, TERMINAL BOARDS, AND THE LIKE, SEE DISTRIBUTION BOX. FOR BOXES DESIGNED TO MOUNT BUT WHICH DO NOT INCLUDE FUSEHOLDERS, SEE JUNCTION BOX. EXCLUDES CHAMBER, CABLE TERMINAL; FUSEHOLDER; AND TERMINAL BOX.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
MIL-DTL-24646/1 | 81349 | M | 4 | 1 | E | ZZ | ||
MIL-F-24646/1 | 81349 | M | 5 | 9 | E | ZZ | ||
M24646/1-002 | 81349 | M | 2 | 2 | E | ZZ | ||
9S5349LTYPED29A | 80064 | A | 5 | 9 | 5 | TX |
CAGE Information
Code | Company |
---|---|
80064 | NAVAL SHIP SYSTEMS COMMAND |
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
FUSES, ARRESTORS, ABSORBERS, AND
Inclusions:
INCLUDES FUSEHOLDERS; FUSE BOXES; FUSE POSTS; FUSE LINKS; FUSE BLOCKS; CURRENT LIMITERS; CORONA BALLS; ELECTROSTATIC DISCHARGERS.
Exclusions:
EXCLUDES CIRCUIT BREAKERS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
BGJP | FUSE TYPE AND QUANTITY ACCOMMODATED | 8 CARTRIDGE FERRULE |
BGJP | FUSE TYPE AND QUANTITY ACCOMMODATED | 8 CARTRIDGE FERRULE |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-F-24646/1 GOVERNMENT SPECIFICATION |
ABFY | OVERALL DEPTH | 4.250 INCHES NOMINAL |
BFXT | SECOND CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE HEIGHT | 6.500 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 16.156 INCHES NOMINAL |
BFXR | FIRST CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE HEIGHT | 6.500 INCHES NOMINAL |
STYL | STYLE DESIGNATOR | RECTANGULAR, SURFACE MOUNTING |
ANDG | FUSE CURRENT RATING IN AMPS | 30.0 |
MATT | MATERIAL | STEEL |
CBBL | FEATURES PROVIDED | COVER |
SFTT | SURFACE TREATMENT | ENAMEL |
AGEJ | SYSTEM FOR WHICH DESIGNED | TWO WIRE SINGLE PHASE |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 8.500 INCHES NOMINAL |
BFYD | MAIN LINE MAXIMUM AC VOLTAGE RATING IN VOLTS | 125.0 |
TEST | TEST DATA DOCUMENT | 81349-MIL-F-24646 SPECIFICATION |
AESL | STANDARD MOUNTING PATTERN DESIGNATOR | 6 POINT-RECTANGULAR |
BFYC | MAIN LINE MAXIMUM CURRENT RATING IN AMPS | 30.0 |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.500 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 10.156 INCHES NOMINAL |
AXGY | MOUNTING METHOD | UNTHREADED HOLE |