NIIN Output Data
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
TS2925-3 | 80249 | A | 3 | 2 | X | XX | ||
367-0509-000 | 13499 | A | 3 | 2 | 5 | CX | ||
600-3 | 83330 | A | 5 | 9 | 5 | CX | ||
600-3M | 83330 | A | 5 | 9 | 5 | CX | ||
8106045 | 18876 | A | 3 | 2 | X | XX | ||
600-GP-03 | 26405 | A | 3 | 2 | 5 | CX | ||
600-JJ-03 | 26405 | A | 3 | 2 | 5 | CX | ||
367-0509-000 | 95105 | A | 5 | 2 | 5 | CX | ||
600C3 | 83330 | A | 5 | 9 | 5 | CX | ||
3-140 | 71785 | A | 5 | 2 | X | XX | ||
331547 | 36090 | A | 5 | 2 | 5 | ZF | ||
140-3 | 71785 | A | 3 | 1 | 6 | CX |
CAGE Information
Code | Company |
---|---|
13499 | ROCKWELL COLLINS INC. DBA GOVERNMENT |
80249 | BAE SYSTEMS INFORMATION AND ELECTRON |
83330 | DIALIGHT CORPORATION |
18876 | U S ARMY AVIATION AND MISSILE COMMAN |
26405 | MARATHON SPECIAL PRODUCTS CORPORATIO |
95105 | ROCKWELL COLLINS INC. DIV GOVERNMENT |
71785 | CINCH CONNECTORS INC. |
36090 | LOCKHEED MARTIN LIBRASCOPE CORP |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 1100.0 |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 1100.0 |
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
ABGS | BASE THICKNESS | 0.250 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
AMPS | CURRENT RATING IN AMPS | 15.0 |
ABGN | BOARD OVERALL LENGTH | 1.750 INCHES |
CWLN | TERMINAL DESIGN | LINKED NONFEEDTHRU |
AAMA | MOUNTING HOLE DIAMETER | 0.160 INCHES |
ABGQ | BOARD OVERALL HEIGHT | 0.406 INCHES |
ABCS | TERMINAL ROW QUANTITY | 2 |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.500 INCHES |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.312 INCHES |
CRNL | NONFEEDTHRU TERMINAL TYPE | 857 SINGLE |
CSCR | TERMINAL CONNECTING LINK TYPE | 2 SINGLE |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.375 INCHES |
ABGP | BOARD OVERALL WIDTH | 0.875 INCHES |
MATT | MATERIAL | COPPER ALLOY TERMINALS |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.406 INCHES |
SFTT | SURFACE TREATMENT | NICKEL TERMINALS |
CQCZ | TERMINAL CONNECTING LINK QUANTITY | 3 SINGLE |
MATT | MATERIAL | PLASTIC PHENOLIC BOARD |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 3 SINGLE |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.281 INCHES |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.312 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.141 INCHES |
AAQL | BODY STYLE | BARRIER TYPE |