NIIN Output Data
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
D660448C | 04773 | F | 3 | 9 | 5 | CX | ||
D66676A | 04773 | F | 5 | 9 | 5 | CX | ||
D660425C | 04773 | F | 5 | 9 | 5 | CL |
CAGE Information
Code | Company |
---|---|
04773 | GTE COMMUNICATION SYSTEMS CORP |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
MATT | MATERIAL | PLASTIC BOARD |
MATT | MATERIAL | PLASTIC BOARD |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
CBBL | FEATURES PROVIDED | FANNING HOLES |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 7.500 INCHES |
CWLN | TERMINAL DESIGN | LATERAL FEEDTHRU |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 1.094 INCHES |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.188 INCHES |
ABGP | BOARD OVERALL WIDTH | 3.375 INCHES |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.344 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.234 INCHES |
ABCS | TERMINAL ROW QUANTITY | 3 |
AAMA | MOUNTING HOLE DIAMETER | 0.344 INCHES |
ABGN | BOARD OVERALL LENGTH | 7.969 INCHES |
ABGS | BASE THICKNESS | 0.750 INCHES |
ABCX | BOARD CONSTRUCTION | CONSTRUCTED OF INTERLOCKING PIECES |
ABGQ | BOARD OVERALL HEIGHT | 2.750 INCHES |
CRZR | FEEDTHRU TERMINAL QUANTITY | 60 SINGLE COMBINATION |
CQCW | FEEDTHRU CONNECTION END TYPE | F18 BOTH ENDS SINGLE COMBINATION |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 1.000 INCHES |
AAQL | BODY STYLE | T-SHAPE |