NIIN Output Data
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
700079 | 10001 | A | 3 | 2 | 1 | CX | ||
K9751102 | 24446 | A | 3 | 2 | X | XX |
CAGE Information
Code | Company |
---|---|
10001 | NAVAIR AND NAVSEA MANAGED ORIGINAL D |
24446 | GENERAL ELECTRIC CO |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
FEAT | SPECIAL FEATURES | FUNGUS AND MOISTURE PROOF |
ABGN | BOARD OVERALL LENGTH | 4.562 INCHES |
PRMT | PRECIOUS MATERIAL | SILVER |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 1.375 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.218 INCHES |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.125 INCHES |
ABCS | TERMINAL ROW QUANTITY | 2 |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.500 INCHES |
CRNL | NONFEEDTHRU TERMINAL TYPE | 434 SINGLE |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 12 SINGLE |
AAQL | BODY STYLE | STRIP TYPE |
CWLN | TERMINAL DESIGN | NONFEEDTHRU |
ABGP | BOARD OVERALL WIDTH | 2.375 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 8 UNTHREADED HOLE |
SFTT | SURFACE TREATMENT | SILVER TERMINALS |
ABGT | BOARD THICKNESS | 0.125 INCHES |
PMLC | PRECIOUS MATERIAL AND LOCATION | TERMINAL SILVER |
MATT | MATERIAL | PLASTIC PHENOLIC BOARD |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.281 INCHES |
AAMA | MOUNTING HOLE DIAMETER | 0.157 INCHES |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.312 INCHES |
MARK | SPECIAL MARKINGS | R2,R6,R8,R9,R10,R11 |