NIIN Output Data
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
700A | 06KW9 | R | 3 | 2 | 5 | ZZ | ||
ESX649314ISSUE12PT35K | 64959 | R | 5 | 9 | X | XX | ||
ESX649314-35K | 06KW9 | R | 3 | 2 | 5 | ZZ | ||
ESX649314ISSUE12 | 70408 | F | 5 | 9 | 5 | CX | ||
ESX649314ISSUE12DT35 | 70408 | F | 5 | 9 | 5 | CX | ||
700A | 70408 | F | 5 | 9 | 5 | CX | ||
ESX649314ISSUE12PT35K | 70408 | F | 5 | 9 | 5 | CX | ||
ESX649314-35K | 64959 | R | 5 | 9 | 5 | CX | ||
700A | 64959 | R | 5 | 9 | X | XX |
CAGE Information
Code | Company |
---|---|
06KW9 | LUCENT TECHNOLOGIES INC DBA FEDERAL |
64959 | AMERICAN TELEPHONE AND TELEGRAPH CO |
70408 | AT AND T CORP |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
ABGP | BOARD OVERALL WIDTH | 1.250 INCHES |
FEAT | SPECIAL FEATURES | LOCATING DOWELL INCLUDED |
ABCS | TERMINAL ROW QUANTITY | 2 |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
AAQL | BODY STYLE | BLOCK TYPE |
CWLN | TERMINAL DESIGN | NONFEEDTHRU |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.625 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.735 INCHES |
CDTD | MOUNTING FACILITY THREAD SERIES DESIGNATOR | UNC |
CRNL | NONFEEDTHRU TERMINAL TYPE | 73 SINGLE |
ABGT | BOARD THICKNESS | 0.938 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED HOLE |
MATT | MATERIAL | PLASTIC PHENOLIC BOARD |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.281 INCHES |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 8 SINGLE |
ABGN | BOARD OVERALL LENGTH | 1.469 INCHES |