NIIN Output Data

NIIN:
NSN:
Item Name:
MOTOR , DIRECT CURRENT

Definition:

A MOTOR WHICH IS DESIGNED FOR OPERATION FROM A DIRECT CURRENT SOURCE. EXCLUDES MOTOR, ENGINE STARTER, ELECTRICAL. SEE ALSO MOTOR, CONTROL.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
MILM17413 81349 M 4 1 X XX
7012F96 24446 A 3 2 5 XX

CAGE Information

Code Company
24446 GENERAL ELECTRIC CO
81349 MILITARY SPECIFICATIONS PROMULGATED

Federal Supply Class

Title

MOTORS, ELECTRICAL

Inclusions:

Exclusions:

EXCLUDES STARTING MOTORS FOR ENGINES.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE
CWCS LENGTH OF SHAFT FROM HOUSING 3.938 INCHES SECOND END
CWGL CURRENT RATING IN AMPS 36.200 SINGLE INPUT
AAJU OVERALL LENGTH 29.188 INCHES
AXCP WINDING TYPE COMPOUND WOUND
ANPZ INCLOSURE FEATURE DRIPPROOF PROTECTED-15 DEG
BKPQ INCLOSURE SPECIFICATION MIL-STD-108
CBBL FEATURES PROVIDED VERTICAL MOUNTING POSITION
CWGQ CONNECTION TYPE AND VOLTAGE RATING IN VOLTS 230.0 LINE TO NEUTRAL SINGLE INPUT
CWCS LENGTH OF SHAFT FROM HOUSING 1.375 INCHES FIRST END
CNXS POWER RATING 10.0000 HORSEPOWER OUTPUT
CWDM SHAFT CENTER TO MOUNTING SURFACE DISTANCE 8.000 INCHES SINGLE END
CWDT NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 10.500 INCHES
CWDY TEMP RATING 50.0 OPERATING DEG CELSIUS
AKPS DUTY CYCLE CONTINUOUS
BFMF COOLING METHOD NATURAL CONVECTION VENTILATED
CWFX ROTOR SPEED RATING IN RPM 1750.0 SINGLE FULL LOAD
AXGY MOUNTING METHOD FIXED BASE
TTQY TERMINAL TYPE AND QUANTITY 6 SOLDER LUG
CWFY NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 12.500 INCHES
BKPB CURRENT RATING METHOD LOAD
AAJT OVERALL HEIGHT 18.500 INCHES
AAJV OVERALL WIDTH 19.156 INCHES