NIIN Output Data
NIIN:
NSN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
C8780-1W | 02858 | H | 5 | 9 | X | XX | ||
5RJ2000G | 78277 | F | 5 | 9 | X | XX | ||
5RJ75910 | 78277 | F | 5 | 9 | X | XX | ||
7481811P1 | 57057 | A | 3 | 2 | 5 | TX | ||
C8780-1W | 94696 | A | 5 | 2 | 5 | TX | ||
20500147 | 57057 | A | 3 | 2 | 5 | TX |
CAGE Information
Code | Company |
---|---|
02858 | SARGENT INDUSTRIES INC |
78277 | SIGMA INSTRUMENTS INC |
57057 | NAVCOM DEFENSE ELECTRONICS INC. |
94696 | SE RELAYS LLC MAGNECRAFT DIV SE RELA |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
AKDX | WINDING QUANTITY | 1 |
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 2.900 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 5 THREADED STUD ALL FUNCTIONS |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
APCN | COIL QUANTITY | 1 |
ABHP | OVERALL LENGTH | 1.500 INCHES NOMINAL |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD SINGLE MOUNTING FACILITY |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES DC RESISTIVE LOAD |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | INERT GAS |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
ABMK | OVERALL WIDTH | 1.500 INCHES NOMINAL |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 24.0 DC |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 2.3 MILLIAMPERES DC SINGLE WINDING |
APNA | WINDING DC RESISTANCE RATING | 2.0 KILOHMS NOMINAL SINGLE WINDING |