NIIN Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
K43J227 | 24446 | A | 3 | 2 | X | XX |
CAGE Information
Code | Company |
---|---|
24446 | GENERAL ELECTRIC CO |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ADAQ | BODY LENGTH | 4.875 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CWJS | WINDING OPERATING VOLTAGE | 5.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
CMLP | THREAD QUANTITY PER INCH | 24 SINGLE GROUP |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 500.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 4TH SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.188 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CRBZ | WINDING OPERATING CURRENT | 6.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY |
AEHZ | MAXIMUM OPERATING TEMP | 60.0 DEG CELSIUS |
ADAT | BODY WIDTH | 4.312 INCHES NOMINAL |
ADAU | BODY HEIGHT | 5.281 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 6.031 INCHES NOMINAL |
CWJS | WINDING OPERATING VOLTAGE | 5.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AAJD | THREAD CLASS (NON-CORE) | 2A SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 5.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
AKNA | INCLOSURE TYPE | OPEN |
TTQY | TERMINAL TYPE AND QUANTITY | 10 FEED THRU |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 12.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |