Follow Us on Google+

Request A Price Quote:

NIIN Output Data

NIIN:
NSN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
7202-24 58657 A 5 9 5 AX
00170-0061 93568 H 3 9 6 AX

CAGE Information

Code Company
58657 LEACH INTERNATIONAL CORPORATION DBA
93568 HARSCO CORP BMY-COMBAT SYSTEMS DIV

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKDX WINDING QUANTITY 1
AKDX WINDING QUANTITY 1
APNP DUTY TYPE INTERMITTENT
ABHP OVERALL LENGTH 4.375 INCHES NOMINAL
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 200.0 AMPERES DC RESISTIVE LOAD
CRPQ NOMINAL OPERATING CURRENT RATING AND TYPE 0.36 AMPERES DC SINGLE WINDING
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 24.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING
APCN COIL QUANTITY 1
ZZZV FSC APPLICATION DATA (NON-CORE) ENGINE STARTING GROUP,DIESEL ENGINE
ABKW OVERALL HEIGHT 3.469 INCHES MINIMUM AND 3.531 INCHES MAXIMUM
ABMK OVERALL WIDTH 2.375 INCHES NOMINAL
APNA WINDING DC RESISTANCE RATING 66.0 OHMS NOMINAL SINGLE WINDING
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 24.0 DC

Similar Parts

7202-24 , 720224 , 5945-00-259-5818 , 5945002595818 , 002595818 , 7202-24 , 00170-0061 ,