NIIN Output Data
NIIN:
NSN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
7202-24 | 58657 | A | 5 | 9 | 5 | AX | ||
00170-0061 | 93568 | H | 3 | 9 | 6 | AX |
CAGE Information
Code | Company |
---|---|
58657 | LEACH INTERNATIONAL CORPORATION DBA |
93568 | HARSCO CORP BMY-COMBAT SYSTEMS DIV |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
AKDX | WINDING QUANTITY | 1 |
APNP | DUTY TYPE | INTERMITTENT |
ABHP | OVERALL LENGTH | 4.375 INCHES NOMINAL |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 200.0 AMPERES DC RESISTIVE LOAD |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 0.36 AMPERES DC SINGLE WINDING |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 24.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
APCN | COIL QUANTITY | 1 |
ZZZV | FSC APPLICATION DATA (NON-CORE) | ENGINE STARTING GROUP,DIESEL ENGINE |
ABKW | OVERALL HEIGHT | 3.469 INCHES MINIMUM AND 3.531 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.375 INCHES NOMINAL |
APNA | WINDING DC RESISTANCE RATING | 66.0 OHMS NOMINAL SINGLE WINDING |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 24.0 DC |