NIIN Output Data
NIIN:
NSN:
Item Name:
AIR CONDITIONER
Definition:
A SELF-CONTAINED UNIT DESIGNED TO PERFORM THE FUNCTIONS OF COOLING, CIRCULATING, FILTERING, DEHUMIDIFYING OR OTHERWISE PROCESSING OF AIR. IT MAY ALSO BE EQUIPPED TO PERFORM THE ADDITIONAL FUNCTIONS OF HEATING OR HUMIDIFYING. IT MAY BE THE AIR CYCLE TYPE USED IN AIRCRAFT OR THE VAPOR CYCLE TYPE APPLICABLE TO GROUND OR AEROSPACE EQUIPMENT. EXCLUDES ENVIRONMENTAL CONTROL UNIT, PERSONNEL, SELF-CONTAINED.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
PA300 | 89863 | A | 3 | 2 | X | XX |
CAGE Information
Code | Company |
---|---|
89863 | HUPP INDUSTRIES INC TYPHOON AIR COND |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ALCD | USAGE DESIGN | COMPRESSOR AND FAN |
ALCD | USAGE DESIGN | COMPRESSOR AND FAN |
AAXX | MOUNTING TYPE | FLOOR |
ARNA | COOLANT TYPE | FREON-12 |
FEAT | SPECIAL FEATURES | COOLING TOWER-NOT INCL.;EVAPORATIVE CONDENSER-NOT INCL.;ACCESSORIES-INCL. |
AMSE | VOLTAGE RATING | 115.0 VOLTS NOMINAL |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL |
AZAD | CONDENSER COOLING TYPE | AIR |
AWLX | ELECTRIC MOTOR QUANTITY | 1 |
ANCY | HORSEPOWER RATING | 3.000 |
CYJE | COOLING CAPACITY IN BTU PER HOUR | 18000.0 NOMINAL |
ACDC | CURRENT TYPE | AC |
AZSF | NOMINAL COOLING CAPACITY | 615.0 CUBIC FEET PER MINUTE |
AZSD | COMPRESSOR UNIT TYPE | OPEN |
ATJK | POWER SOURCE | ELECTRIC MOTOR |
FAAZ | PHASE | SINGLE |