NIIN Output Data
NIIN:
NSN:
Item Name:
HEATER , VEHICULAR , COMPARTMENT
Definition:
A DEVICE DESIGNED TO HEAT THE INTERIOR OF A VEHICLE BY UTILIZING THE HEAT FROM THE ENGINE COOLANT SYSTEM OR A LIQUID FUEL TYPE BURNER. CIRCULATION OF THE HEATED AIR IS ACHIEVED BY USE OF A BLOWER OR FAN WHICH MAY OR MAY NOT BE AN INTEGRAL PART OF THE HEATING UNIT. EXCLUDES HEATER, AIRCRAFT, AND RAILWAY HEATERS.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
8366993 | 19207 | A | 5 | 2 | X | XX | ||
E15241G3 | 46522 | A | 3 | 2 | X | XX |
CAGE Information
Code | Company |
---|---|
19207 | U S ARMY TANK AUTOMOTIVE COMMAND AMS |
46522 | DCM MANUFACTURING INC. |
Federal Supply Class
Title
VEHICULAR FURNITURE AND ACCESSOR
Inclusions:
INCLUDES AUTOMOBILE SEAT COVERS; SHOCK ABSORBERS; BUMPERS; WINDSHIELD WIPERS; BUMPER GUARDS; MIRRORS, REAR VIEW AND SIDE VIEW; VEHICLE HEATERS.
Exclusions:
EXCLUDES SPEEDOMETERS (FSC 6680); SUSPENSION TYPE SHOCK ABSORBERS (FSC 2510).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABAW | HEAT OUTLET QUANTITY | 1 |
ABAW | HEAT OUTLET QUANTITY | 1 |
ABBA | AIR CIRCULATION DEVICE | PROPELLER FAN |
BDXJ | HEATING ELEMENT TYPE | BURNER |
CQTY | FUEL CONSUMPTION RATE PER HOUR | 4.0 GALLONS |
HGTH | HEIGHT | 10.468 INCHES NOMINAL |
AAXX | MOUNTING TYPE | ANY ACCEPTABLE |
ABAY | HEAT DISCHARGE OUTLET TYPE | STATIONARY |
ABAZ | HEAT DIRECTING DEVICE | FIXED LOUVER |
NMBR | QUANTITY | 1 |
ACDC | CURRENT TYPE | DC |
ABBD | MAXIMUM AIR FLOW RATE | 71.0 CUBIC FEET PER MINUTE |
AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
ALYC | OPERATING CONTROL TYPE | HAND SWITCH |
ABAX | HEAT DELIVERY DIRECTION | HORIZONTAL |
ABFG | RADIO INTERFERENCE SUPPRESSION TYPE | ARMY, MIL-S-10379, RADIO SUPPRESSION |
CQXD | HEAT DELIVERY RATE | 32400.0 BRITISH THERMAL UNIT |
ABMZ | DIAMETER | 6.031 INCHES NOMINAL |
ABBE | CIRCULATED AIR TYPE | HEATED |
FUEL | FUEL TYPE | 80/87 OCTANE GASOLINE |
CSGC | FUEL FEED METHOD | INTERNAL PUMP |
AMPS | CURRENT RATING IN AMPS | 6.0 |
ABAN | MAXIMUM PRESSURE LIMIT | 2.0 POUNDS PER SQUARE INCH GAGE |
SFTT | SURFACE TREATMENT | ENAMEL |
ABAM | HEAT MEDIUM TYPE | AIR |
BLJC | IGNITION METHOD | ELECTRODE |
ABFH | FLUE CONNECTION LOCATION | EXHAUST TUBE LOCATED ON BOTTOM 0F HEATER |
ELEC | VOLTAGE IN VOLTS | 24.0 |
CQSJ | INCLOSURE MATERIAL | STEEL CORROSION RESISTING |
ABBB | SPEED ADJUSTMENTS | SIX SPEED |