NIIN Output Data
NIIN:
NSN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
950122-001B | 82577 | A | 5 | 2 | 5 | TX | ||
950122-1B | 82577 | A | 5 | 2 | A | TX | ||
9324-8843 | 58657 | A | 3 | 2 | E | TX |
CAGE Information
Code | Company |
---|---|
58657 | LEACH INTERNATIONAL CORPORATION DBA |
82577 | RAYTHEON COMPANY DBA RAYTHEON |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
AKDX | WINDING QUANTITY | 1 |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.173 INCHES NOMINAL SINGLE MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
ABKW | OVERALL HEIGHT | 2.460 INCHES MAXIMUM |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC LAMP LOAD AND 5.0 AMPERES DC LAMP LOAD |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
APCN | COIL QUANTITY | 1 |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 20.0 AMPERES AC MOTOR LOAD AND 20.0 AMPERES DC MOTOR LOAD |
CRXH | TIME DELAY | 0.02 SECONDS MAXIMUM FIXED OPERATE TIME |
ABMK | OVERALL WIDTH | 1.465 INCHES MAXIMUM |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 15.0 AMPERES AC INDUCTIVE LOAD AND 20.0 AMPERES DC INDUCTIVE LOAD |
ABHP | OVERALL LENGTH | 2.500 INCHES MAXIMUM |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
APNQ | ARC QUENCHING METHOD | AIR |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
CBME | CUBIC MEASURE | 9.009 CUBIC INCHES |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APNP | DUTY TYPE | CONTINUOUS |
ADTV | CASE MATERIAL | METAL |
CRXH | TIME DELAY | 0.01 SECONDS MAXIMUM FIXED RELEASE TIME |
TTQY | TERMINAL TYPE AND QUANTITY | 8 SCREW ALL FUNCTIONS |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 20.0 AMPERES AC RESISTIVE LOAD AND 20.0 AMPERES DC RESISTIVE LOAD |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.062 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
Similar Parts
9324-8843 ,
93248843 ,
5945-00-324-3216 ,
5945003243216 ,
003243216
,
950122-001B ,
950122-1B ,
9324-8843 ,