NIIN Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
D49463 | 28455 | A | 5 | 2 | 5 | TX | ||
D49463-3 | 28455 | A | 3 | 2 | 1 | TX |
CAGE Information
Code | Company |
---|---|
28455 | HEVI DUTY ELECTRIC SOLA BASIC INDUST |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND SLOT SINGLE GROUP |
CQLC | WINDING TAP LOCATION (NON-CORE) | TAP W/CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
ADAU | BODY HEIGHT | 3.188 INCHES NOMINAL |
CQLC | WINDING TAP LOCATION (NON-CORE) | MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE SECONDARY |
AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED, DOUBLE SHELL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.219 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
TTQY | TERMINAL TYPE AND QUANTITY | 8 TAB, SOLDER LUG |
ADAQ | BODY LENGTH | 4.250 INCHES NOMINAL |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 480.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ABTD | MOUNTING SLOT WIDTH | 0.203 INCHES NOMINAL SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 15.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY AND 30.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY AND 41.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ADAT | BODY WIDTH | 3.750 INCHES NOMINAL |