NIIN Output Data

NIIN:
NSN:
Item Name:
PUMP UNIT , CENTRIFUGAL

Definition:

AN ASSEMBLED UNIT CONSISTING OF A COMMONLY MOUNTED CENTRIFUGAL PUMP(S), PRIME MOVER(S), AND THE NECESSARY COMPONENTS TO PROVIDE FOR A COMPLETE OPERATION.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
145547-1 24930 A 1 2 1 PA
9420CA924 95270 A 3 2 5 PA

CAGE Information

Code Company
24930 ITT CORPORATION DBA ITT ELECTRONICS
95270 SKURKA AEROSPACE INC.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AHZF CENTRIFUGAL PUMP IMPELLER QUANTITY 1
AHZF CENTRIFUGAL PUMP IMPELLER QUANTITY 1
AHZV SUBMERSIBILITY (NON-CORE) NONSUBMERSIBLE
ADZC ENVIRONMENTAL PROTECTION DRIPPROOF
AAXS PRIME MOVER COOLING MEDIUM AIR
AAYU INTAKE CONNECTION TYPE THREADED INTERNAL
CBBL FEATURES PROVIDED SELF-PRIMING
ACKL MEDIA FOR WHICH DESIGNED ETHYLENE GLYCOL AND WATER, FRESH
ELEC VOLTAGE IN VOLTS 208.0
AENC PUMP QUANTITY 1
ASAZ DISCHARGE CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR 1.125-11-1/2 NPT
AKDJ PRIME MOVER TYPE ELECTRIC MOTOR
AHZG CENTRIFUGAL PUMP IMPELLER SUCTION TYPE SINGLE
FAAZ PHASE THREE
AAYW DISCHARGE CONNECTION TYPE THREADED INTERNAL
AHYY SUCTION LIFT 22.000 FEET
AHZA PUMPING ELEMENT OPERATING POSITION HORIZONTAL
AHYX TOTAL HEAD 161.000 FEET
AAYT INTAKE CONNECTION QUANTITY 1
ASWT INTAKE CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR 1.125-11-1/2 NPT
AENK COOLING METHOD AIR TO AIR COOLED
AAXH PRIME MOVER QUANTITY 1
AHYV MAXIMUM DISCHARGE FLOW RATE 17.5 GALLONS PER MINUTE
AAYD STAGE QUANTITY 1
AAYV DISCHARGE CONNECTION QUANTITY 1
AHYZ OPERATING SPEED AT RATED CAPACITY 1800.0 REVOLUTIONS PER MINUTE
AAXX MOUNTING TYPE BASE
ACDC CURRENT TYPE AC
AKNA INCLOSURE TYPE PARTIALLY INCLOSED
AHZE CENTRIFUGAL PUMP DESIGN RADIAL FLOW
FREQ FREQUENCY IN HERTZ 400.0

Similar Parts

145547-1 , 1455471 , 4320-00-403-3254 , 4320004033254 , 004033254 , 145547-1 , 9420CA924 ,