Follow Us on Google+

Request A Price Quote:

NIIN Output Data

NIIN:
NSN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
9T21A4014 03512 F 5 9 5 CX
9T21A4014G2 03512 F 3 2 5 CX

CAGE Information

Code Company
03512 GENERAL ELECTRIC CO SPECIALTY TRANSF

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKNA INCLOSURE TYPE PARTIALLY INCLOSED, DOUBLE SHELL
AKNA INCLOSURE TYPE PARTIALLY INCLOSED, DOUBLE SHELL
ADAU BODY HEIGHT 7.875 INCHES NOMINAL
ACZF MAXIMUM TRANSFORMER POWER RATING 6.0 KILOVOLT-AMPERE SINGLE COMPONENT
ADAQ BODY LENGTH 25.312 INCHES NOMINAL
BFMF COOLING METHOD SELF-COOLED
ACZC INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO THREE PHASE SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 240.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY
TTQY TERMINAL TYPE AND QUANTITY 8 WIRE LEAD
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
ADAT BODY WIDTH 9.125 INCHES NOMINAL
CWJS WINDING OPERATING VOLTAGE 468.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 492.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 480.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 456.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 504.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
CQLC WINDING TAP LOCATION (NON-CORE) MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY
ACZB FREQUENCY RATING 60.0 HERTZ NOMINAL SINGLE COMPONENT

Similar Parts

9T21A4014 , 9T21A4014 , 5950-00-433-5962 , 5950004335962 , 004335962 , 9T21A4014 , 9T21A4014G2 ,