Follow Us on Google+

Request A Price Quote:

NIIN Output Data

NIIN:
NSN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
43524 73386 A 5 2 A TX
77C708731P1 03538 A 7 2 1 HD
9T35Y2225 03512 F 3 2 6 HH

CAGE Information

Code Company
03512 GENERAL ELECTRIC CO SPECIALTY TRANSF
73386 FREED TRANSFORMER COMPANY
03538 LOCKHEED MARTIN CORPORATION DBA MS2

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
CRBZ WINDING OPERATING CURRENT 2.86 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY
ADAU BODY HEIGHT 5.250 INCHES MAXIMUM
TTQY TERMINAL TYPE AND QUANTITY 9 TAB, SOLDER LUG
ADAT BODY WIDTH 3.380 INCHES MAXIMUM
ACZC INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO THREE PHASE SINGLE COMPONENT
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
ADAQ BODY LENGTH 3.940 INCHES MAXIMUM
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ACZX WINDING SHIELDING METHOD EXTERNAL INCLOSURE SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 22.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
AKNA INCLOSURE TYPE HERMETICALLY SEALED
AXGY MOUNTING METHOD THREADED STUD SINGLE GROUP
CRMJ WINDING POWER RATING 110.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY
CWJS WINDING OPERATING VOLTAGE 208.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT
ABKW OVERALL HEIGHT 5.770 INCHES MAXIMUM
CRBZ WINDING OPERATING CURRENT 28.6 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY
CMLP THREAD QUANTITY PER INCH 32 SINGLE GROUP
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
THSD THREAD SERIES DESIGNATOR UNF SINGLE GROUP
AAJD THREAD CLASS (NON-CORE) 2A SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 20.20 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
CQJX NOMINAL THREAD SIZE 0.190 INCHES SINGLE GROUP
ACZB FREQUENCY RATING 60.0 HERTZ NOMINAL SINGLE COMPONENT

Similar Parts

9T35Y2225 , 9T35Y2225 , 5950-00-436-6256 , 5950004366256 , 004366256 , 43524 , 77C708731P1 , 9T35Y2225 ,