NIIN Output Data
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
PJ610 | 00144 | A | 3 | 2 | 4 | CX |
CAGE Information
Code | Company |
---|---|
00144 | ADC TELECOMMUNICATIONS INC. DIV ADC |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
MATT | MATERIAL | PLASTIC BOARD |
CWKZ | MOUNTING FACILITY NOMINAL THREAD DIAMETER | 0.138 INCHES |
CWLN | TERMINAL DESIGN | LATERAL FEEDTHRU |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.750 INCHES |
ABCS | TERMINAL ROW QUANTITY | 10 |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.250 INCHES |
CQCW | FEEDTHRU CONNECTION END TYPE | F6 BOTH ENDS SINGLE COMBINATION |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.875 INCHES |
CRZR | FEEDTHRU TERMINAL QUANTITY | 100 SINGLE COMBINATION |
ABGS | BASE THICKNESS | 0.093 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.375 INCHES |
CDTD | MOUNTING FACILITY THREAD SERIES DESIGNATOR | UNC |
MATT | MATERIAL | COPPER ALLOY TERMINALS |
ABGP | BOARD OVERALL WIDTH | 1.750 INCHES |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.250 INCHES |
AAQL | BODY STYLE | T-SHAPE |
ABGQ | BOARD OVERALL HEIGHT | 3.188 INCHES |
ABGN | BOARD OVERALL LENGTH | 2.500 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD |