Follow Us on Google+

Request A Price Quote:

NIIN Output Data

NIIN:
NSN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
DJL26C1P6A9 99699 A 5 2 5 TX
CVC6051-1 80378 A 3 2 1 TX

CAGE Information

Code Company
80378 TRIUMPH AEROSTRUCTURES, LLC DBA TRIU
99699 DRI RELAYS INC.

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
ABMK OVERALL WIDTH 0.580 INCHES NOMINAL
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY
AKDX WINDING QUANTITY 2
TTQY TERMINAL TYPE AND QUANTITY 10 PIN ALL FUNCTIONS
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 26.5 VOLTS TEARDROP, TWO HOLES TYPE 4F ALL WINDINGS
APCN COIL QUANTITY 2
ABKW OVERALL HEIGHT 0.400 INCHES NOMINAL
CBBL FEATURES PROVIDED LATCHING CONTACTS
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 28.0 DC
ADZC ENVIRONMENTAL PROTECTION HERMETIC
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 1.0 AMPERES AC RESISTIVE LOAD AND 1.0 AMPERES DC RESISTIVE LOAD
APNP DUTY TYPE CONTINUOUS
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
ABHP OVERALL LENGTH 0.800 INCHES NOMINAL

Similar Parts

CVC6051-1 , CVC60511 , 5945-00-479-7955 , 5945004797955 , 004797955 , DJL26C1P6A9 , CVC6051-1 ,