NIIN Output Data
NIIN:
NSN:
Item Name:
RESISTOR , FIXED , WIRE WOUND , INDUCT
Definition:
INC 37403 REINSTATED ON 010303~A RESISTOR WHOSE OHMIC VALUE CANNOT BE ADJUSTED OR VARIED. THE RESISTANCE ELEMENT CONSISTS OF HIGH RESISTANCE WIRE (OR RIBBON) EITHER WOUND ON AN INSULATED FORM OR CONSTRUCTED SO AS TO BE SELF-SUPPORTING. THE ITEM MUST HAVE INHERENT CHARACTERISTICS OF INDUCING SELF-INDUCTANCE. OPPOSITION TO CURRENT FLOW IS AN INHERENT PROPERTY OF THE RESISTANCE WIRE AND IS MANIFESTED BY THE HEAT DISSIPATION IN THE RESISTOR. EXCLUDES SUPPRESSOR, IGNITION INTERFERENCE. SEE ALSO RESISTOR (1), FIXED, WIRE WOUND, NONINDUCTIVE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
1240S 82000J | 00213 | A | 5 | 9 | 5 | TX | ||
VL3-8200J | 24681 | A | 5 | 2 | 5 | TX | ||
308-0286-00 | 80009 | A | 3 | 2 | 5 | CL | ||
CW-2B 8.2K OHMS 5% | 91637 | A | 5 | 2 | 5 | ZZ | ||
SA30 8201J | 53655 | A | 5 | 9 | 5 | TX | ||
CW2B 82000J | 91637 | A | 5 | 9 | 5 | TX | ||
443S8200J | 44655 | A | 5 | 2 | 5 | TX | ||
KM300 8.2 K OHM 5 PE | 19587 | F | 5 | 9 | 5 | TX |
CAGE Information
Code | Company |
---|---|
00213 | STRUTHERS-DUNN LLC |
24681 | MEMCOR INC DBA MEMCOR-TRUOHM |
80009 | TEKTRONIX INC. DBA TEKTRONIX |
91637 | VISHAY DALE ELECTRONICS INC. DIV VIS |
53655 | AVOX SYSTEMS INC. |
44655 | HEICO OHMITE L.L.C. DBA OHMITE MANUF |
19587 | KELVIN INDUSTRIES INC |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABPM | BODY DIAMETER | 0.234 INCHES MAXIMUM |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 25.0 |
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -200.0/+200.0 |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
AAPP | ELECTRICAL RESISTANCE | 8.200 KILOHMS |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0/+275.0 |
AARB | TERMINAL TYPE | WIRE LEAD |
ABJT | TERMINAL LENGTH | 1.375 INCHES MINIMUM AND 1.625 INCHES MAXIMUM |
AEFB | POWER DISSIPATION RATING IN WATTS | 3.000 FREE AIR |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 275.0 |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -5.000/+5.000 |
ADAQ | BODY LENGTH | 0.437 INCHES MINIMUM AND 0.563 INCHES MAXIMUM |