NIIN Output Data
NIIN:
NSN:
Item Name:
MANIFOLD , GAS CYLINDER
Definition:
A DEVICE DESIGNED TO ACCOMMODATE THE ATTACHMENT OF TWO OR MORE GAS CYLINDERS TO PERMIT CENTRALIZATION OF SUPPLY AND PROVIDE LARGE QUANTITIES OF GAS AT CONSTANT PRESSURE TO SINGLE OUTLET OR SERVICE LINE. EXCLUDES ITEMS WITH FACILITIES FOR CHARGING OR RECHARGING THE CYLINDERS CONNECTED THERETO.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
M21-150PSI | 36346 | A | 3 | 2 | X | XX |
CAGE Information
Code | Company |
---|---|
36346 | UNION CARBIDE CORP SUB OF DOW CO THE |
Federal Supply Class
Title
GAS GENERATING AND DISPENSING SY
Inclusions:
Exclusions:
EXCLUDES METEOROLOGICAL EQUIPMENT.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AQXN | BANK QUANTITY PER ROW | 2 |
AENF | SPECIFIC GAS FOR WHICH DESIGNED | ARGON |
AQXW | HYDRAULIC BACK PRESSURE VALVE | NOT INCLUDED |
AQXR | FLEXIBLE PIGTAIL LEAD QUANTITY | 8 |
AQXQ | FLEXIBLE PIGTAIL LEAD | INCLUDED |
AQXL | ROW ARRANGEMENT | SINGLE |
AQXS | PIGTAIL FLASH ARRESTOR | NOT INCLUDED |
AAXX | MOUNTING TYPE | WALL |
AQXP | INLET CONNECTION QUANTITY | 8 |
AQXT | INDIVIDUAL CYLINDER SHUT-OFF VALVE | NOT INCLUDED |
AMQY | INSTALLATION DESIGN | FIXED STATION |
AKYD | ACCESSORY COMPONENTS AND QUANTITY | 6 EXTENSION,CYLINDER,STRAIGHT,PART NO. 25X03 |
AQXX | INLET PLUG | INCLUDED |