NIIN Output Data
Definition:
AN ENCLOSURE WHICH INCLUDES MOUNTS, AND PROTECTS SUCH ITEMS AS SWITCHES, CIRCUIT BREAKERS, JACKS, FUSEHOLDERS, CONNECTORS, TERMINALS AND/OR TERMINAL BOARDS, RESISTORS, CAPACITORS, TRANSFORMERS, AND THE LIKE. IT IS PRIMARILY DESIGNED TO DISTRIBUTE ELECTRICAL POWER FROM ONE OR MORE PRIMARY POWER SOURCE(S) SUCH AS GENERATOR(S) AND BATTERY(IES) TO ONE OR MORE ELECTRICAL AND/OR ELECTRONIC ITEM(S). IT MAY INCLUDE A COVER OR DOOR. FOR ENCLOSURES WHICH INCLUDE ONLY CIRCUIT BREAKERS, SWITCHES, JACKS, FUSEHOLDERS, TERMINALS AND/OR TERMINAL BOARDS, SEE CIRCUIT BREAKER BOX; SWITCH BOX; JACK BOX; FUSE BOX AND TERMINAL BOX. FOR ENCLOSURE PRIMARILY DESIGNED TO INTERCONNECT TWO OR MORE ELECTRICAL AND/OR ELECTRONIC ITEMS, EXCEPT PRIMARY POWER SOURCE(S) SEE INTERCONNECTING BOX. FOR EMPTY BOXES WHICH ARE DESIGNED TO MOUNT, BUT DO NOT INCLUDE ELECTRICAL DEVICES SUCH AS SWITCHES, JACKS, FUSEHOLDERS, TERMINALS AND/OR TERMINAL BOARDS, SEE JUNCTION BOX. SEE ALSO INTERCONNECTING CABINET; CONTROL (AS MODIFIED); PANEL (1) (AS MODIFIED); RELAY ASSEMBLY; PANEL, POWER DISTRIBUTION; SWITCHBOARD (AS MODIFIED) AND PANEL, FUSE. EXCLUDES CONNECTOR-SWITCH.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
40023 | 0C9D4 | H | 5 | 9 | 1 | KE | ||
20073-1 | 0C9D4 | H | 5 | 9 | 5 | KE | ||
368458-17 | 00752 | A | 5 | 2 | 1 | KE | ||
40023 | 9N770 | A | 5 | 2 | 1 | KE | ||
20073-1 | 9N770 | A | 3 | 2 | 5 | KE |
CAGE Information
Code | Company |
---|---|
00752 | EDO CORP DIV EDO CORPORATION ANTENNA |
0C9D4 | HARRIS TECHNICAL SERVICES CORP |
9N770 | TELEPHONICS CORP/PRD INSTRUMENTS |
Federal Supply Class
Title
ELECTRICAL CONTROL EQUIPMENT
Inclusions:
INCLUDES CONTACTORS; MOTOR CONTROLLERS; POWER SERVOMECHANISMS; SWITCHGEAR; VOLTAGE REGULATORS.
Exclusions:
EXCLUDES AUTOMATIC PILOT MECHANISMS; RELAYS; RESISTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 6.750 INCHES NOMINAL |
AWAZ | MOUNTING FACILITY THREAD SIZE | 0.190-32 UNF |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 2.250 INCHES NOMINAL |
CCFF | TERMINAL TYPE AND QUANTITY | CONNECTOR RECEPTACLE 4 |
AXGY | MOUNTING METHOD | CAPTIVE SCREWS |
AESL | STANDARD MOUNTING PATTERN DESIGNATOR | 4 POINT-RECTANGULAR |