Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
415191-7-Y | 80020 | A | 3 | 2 | 1 | CX | ||
PVC105-7-Y | 92194 | Y | 5 | 9 | 3 | CX | ||
GLITEX 120 | 05178 | A | 5 | 1 | 3 | CX | ||
HT105-7-Y | 03890 | A | 5 | 1 | 3 | CX | ||
3002 | 75037 | A | 5 | 9 | 3 | CX | ||
NATVAR 261 | 96904 | A | 3 | 1 | 4 | CX | ||
0343-052 | 42470 | A | 5 | 2 | 5 | CX | ||
3002 | 20999 | A | 5 | 9 | 3 | CX | ||
ASTRA 701 | 91094 | F | 5 | 1 | 3 | CX | ||
ITCO 919 | 12509 | A | 5 | 1 | 5 | CX | ||
HYFLEX TRANSFLEX | 75037 | A | 5 | 9 | 3 | CX | ||
5021-14-04 | 03890 | A | 5 | 2 | 5 | ZZ | ||
SURCO B-5 | 90484 | A | 5 | 1 | 5 | CX | ||
PVC-105-14-4 | 92194 | Y | C | 1 | 5 | ZZ | AC | |
HYFLEX TRANSFLEX | 20999 | A | 5 | 9 | 3 | CX | ||
MIL-I-631 | 81349 | M | 4 | 1 | 4 | CX |
CAGE Information
Code | Company |
---|---|
03890 | MARKEL CORP. |
80020 | NAVAL AIR WARFARE CENTER AIRCRAFT DI |
92194 | ALPHA WIRE CORP |
05178 | NALGE CO DIV OF SYBRON CORP |
75037 | MINNESOTA MINING AND MFG CO 3M COMPA |
96904 | HIGH VOLTAGE ENGINEERING CORP NATVAR |
42470 | NCR CORPORATION DBA NCR |
20999 | 3M CO ADMININISTRATIVE ELECTRONIC & |
91094 | ESSEX GROUP INC SUFLEX/IWP DIV |
12509 | INSULTAB INC |
90484 | ROCKBESTOS-SURPRENANT CABLE CORP |
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
FLEX | FLEXIBILITY | FLEXIBLE |
ABHP | OVERALL LENGTH | ANY ACCEPTABLE |
AAGT | WALL THICKNESS | 0.013 INCHES MINIMUM AND 0.019 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 800.0 VOLTS PER MIL /0.001 INCH/ |
STYL | STYLE DESIGNATOR | NONSHRINKABLE |
AARX | INSIDE DIAMETER | 0.064 INCHES MINIMUM AND 0.072 INCHES MAXIMUM |
CQBC | MINIMUM TENSILE STRENGTH | 1800 POUNDS PER SQUARE INCH |
ZZZT | NONDEFINITIVE SPEC/STD DATA | A GRADE AND 1 CATEGORY AND U FORM AND UA SUBFORM AND I CLASS AND 14AWG SIZE AND F TYPE |
MATL | MATERIAL | PLASTIC, POLYVINYL CHLORIDE, MIL-I-631, TYPE F, FORM U, GRADE A, CLASS 1, CATEGORY 1 |
ADZC | ENVIRONMENTAL PROTECTION | MILDEW RESISTANT AND FLAME RESISTANT AND OIL RESISTANT |
ZZZX | DEPARTURE FROM CITED DESIGNATOR | AS MOD BY COLOR |
ABJH | TEMP RATING | -30.0 DEG CELSIUS AND 75.0 DEG CELSIUS |
HUES | COLOR | YELLOW |