NIIN Output Data
NIIN:
NSN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
KHX138 | 02288 | A | 5 | 9 | 1 | TX | ||
RD25453-1 | 00724 | A | 3 | 2 | 1 | TX |
CAGE Information
Code | Company |
---|---|
00724 | RAYTHEON COMPANY DBA RAYTHEON |
02288 | ALLIED CONTROLS INC. |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
ABMK | OVERALL WIDTH | 1.430 INCHES NOMINAL |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
APCN | COIL QUANTITY | 1 |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
APNA | WINDING DC RESISTANCE RATING | 675.0 OHMS NOMINAL SINGLE WINDING |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED STUD SINGLE MOUNTING FACILITY |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES AC RESISTIVE LOAD |
APNP | DUTY TYPE | CONTINUOUS |
AYSC | PILE-UP MAIN CONTACT FORM ARRANGEMENT | 2C |
ABKW | OVERALL HEIGHT | 1.620 INCHES NOMINAL |
ABHP | OVERALL LENGTH | 2.060 INCHES NOMINAL |
CTYK | ANGLE BETWEEN ADJACENT MOUNTING FACILITIES | 105.0 DEGREES NOMINAL SINGLE MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
CQYJ | MOUNTING FACILITY PATTERN | CIRUCLAR SINGLE MOUNTING FACILITY |