NIIN Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
962090 | 29111 | F | 5 | 9 | 2 | SB | ||
962090 | 01220 | F | 3 | 9 | 5 | SB |
CAGE Information
Code | Company |
---|---|
01220 | SYSTRON-DONNER CORP MICROWAVE/INSTRU |
29111 | TRAK MICROWAVE CORP-WESTERN DIV |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.688 INCHES NOMINAL 2ND MOUNTING FACILITY SINGLE CENTER GROUP |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.312 INCHES NOMINAL 3RD MOUNTING FACILITY SINGLE CENTER GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
AKPV | MOUNTING FACILITY QUANTITY | 5 1ST GROUP |
ADAT | BODY WIDTH | 3.688 INCHES NOMINAL |
CWJS | WINDING OPERATING VOLTAGE | 176.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND ALL GROUPINGS |
ACZB | FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CWJS | WINDING OPERATING VOLTAGE | 104.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT ALL PRIMARY AND 115.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT ALL PRIMARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.650 INCHES NOMINAL 1ST MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXGY | MOUNTING METHOD | THREADED STUD ALL GROUPINGS |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES ALL GROUPINGS |
ADAQ | BODY LENGTH | 4.312 INCHES NOMINAL |
CRBZ | WINDING OPERATING CURRENT | 50.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.718 INCHES NOMINAL 1ST MOUNTING FACILITY SINGLE CENTER GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
THSD | THREAD SERIES DESIGNATOR | UNC ALL GROUPINGS |
ADAU | BODY HEIGHT | 4.525 INCHES NOMINAL |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.250 INCHES NOMINAL 3RD MOUNTING FACILITY SINGLE CENTER GROUP |
CQLC | WINDING TAP LOCATION (NON-CORE) | TAP W/O CENTER TAP SINGLE COMPONENT ALL PRIMARY |
AAJD | THREAD CLASS (NON-CORE) | 2A ALL GROUPINGS |
AKPV | MOUNTING FACILITY QUANTITY | 4 2ND GROUP |
CRBZ | WINDING OPERATING CURRENT | 2.5 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
AKPV | MOUNTING FACILITY QUANTITY | 4 3RD GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 12 WIRE LEAD |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.312 INCHES NOMINAL 2ND MOUNTING FACILITY SINGLE CENTER GROUP |
CWJS | WINDING OPERATING VOLTAGE | 25.10 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 32.70 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |