NIIN Output Data
Definition:
AN ELECTRICAL ITEM (THE WORKING ELEMENT OF WHICH IS CONSTRUCTED ESSENTIALLY OF METALLIC SUBSTANCES) WHICH CHANGES ALTERNATING CURRENT TO DIRECT CURRENT BY THE RECTIFYING ACTION OCCURRING AT THE JUNCTION INTERFACE BETWEEN A METALLIC CONDUCTOR AND A SEMICONDUCTOR. EXCLUDES SETS OF METALLIC RECTIFIERS WHICH ARE NOT RATED FOR RECTIFYING CAPABILITIES BUT ARE USED AS SUPPRESSORS. FOR ITEMS CONTAINING GERMANIUM OR SILICON, SEE SEMICONDUCTOR DEVICE (1), DIODE; SEMICONDUCTOR DEVICE SET AND RECTIFIER, SEMICONDUCTOR DEVICE. FOR A COMPLETE POWER SUPPLY UTILIZING METALLIC RECTIFIERS, SEE POWER SUPPLY.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
JR0018 | 3E191 | A | 5 | 2 | X | XX | ||
D1768 | 81483 | A | 3 | 2 | X | XX |
CAGE Information
Code | Company |
---|---|
3E191 | RAULAND-BORG CORPORATION |
81483 | INTERNATIONAL RECTIFIER CORPORATION |
Federal Supply Class
Title
CONVERTERS, ELECTRICAL, NONROTAT
Inclusions:
INCLUDES COMPLETE BATTERY CHARGING EQUIPMENT, NONROTATING; POWER SUPPLIES, MULTIAPPLICATION.
Exclusions:
EXCLUDES RECTIFYING TUBES; (FSC 5960); RECTIFYING CRYSTALS (FSC 5961); ROTATING EQUIPMENT (FSC 6125); TRANSFORMERS (FSC 5950); AND SEMICONDUCTOR DEVICES AND ASSOCIATED HARDWARE (FSC 5961).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABJH | TEMP RATING | 35.0 DEG CELSIUS |
ASDS | GROUNDED TERMINAL | NOT INCLUDED |
ADZC | ENVIRONMENTAL PROTECTION | MOISTURE |
AGAV | END ITEM IDENTIFICATION | TYPE NO. PP-109/GR AND PP-112/GR |
ASCW | DC OUTPUT MAXIMUM CURRENT RATING | 23.000 MILLIAMPERES |
ADAV | OVERALL DIAMETER | 0.750 INCHES NOMINAL |
AJUR | CIRCUIT CONNECTION STYLE DESIGNATOR | CENTER TAP 1 PHASE |
ABHP | OVERALL LENGTH | 0.500 INCHES NOMINAL |
ASCX | LOAD TYPE | INDUCTIVE |
AARB | TERMINAL TYPE | WIRE LEAD |
MATL | MATERIAL | SELENIUM |
ASCY | DC OUTPUT MAXIMUM VOLTAGE RATING | NOT RATED |
ASCT | RMS INPUT MAXIMUM VOLTAGE RATING | 78.0 VOLTS |
ANPZ | INCLOSURE FEATURE | METAL CASE |
AARA | TERMINAL QUANTITY | 3 |
ASCZ | STACK QUANTITY | 1 |