Follow Us on Google+

Request A Price Quote:

NIIN Output Data

NIIN:
NSN:
Item Name:
STARTER , MOTOR

Definition:

A DEVICE PRIMARILY DESIGNED TO CONTROL THE SUPPLY CIRCUIT(S) OF A MOTOR IN ORDER TO ACCELERATE THE MOTOR FROM REST TO NORMAL SPEED. INCLUDES MANUAL STARTERS WITH OVERLOAD PROTECTION AND MANUAL, AUTOMATIC OR SEMIAUTOMATIC STARTERS CONSISTING OF COMBINATIONS OF ITEMS SUCH AS RELAYS, RESISTORS, SWITCHES, CIRCUIT BREAKERS, ETC. EXCLUDES RELAY-SWITCH; CIRCUIT BREAKER; SWITCH (AS MODIFIED) AND RELAY (AS MODIFIED). FOR DEVICES, WHICH IN ADDITION TO STARTING AND STOPPING, REVERSE, SELECT AND/OR REGULATE THE SPEED OF A MOTOR, SEE CONTROLLER (AS MODIFIED).

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
MILC2174SIZE2 81349 M 4 1 E XX
6942ED965-1 15605 A 5 2 6 HD
6942ED965-1MF10HP9104H3964 15605 A 5 2 X XX
942-1-101M14 15605 A 5 2 1 HD
942-1-101M4 15605 A 3 1 X XX

CAGE Information

Code Company
15605 EATON CORP OPNS & TECHNICAL CENTER
81349 MILITARY SPECIFICATIONS PROMULGATED

Federal Supply Class

Title

ELECTRICAL CONTROL EQUIPMENT

Inclusions:

INCLUDES CONTACTORS; MOTOR CONTROLLERS; POWER SERVOMECHANISMS; SWITCHGEAR; VOLTAGE REGULATORS.

Exclusions:

EXCLUDES AUTOMATIC PILOT MECHANISMS; RELAYS; RESISTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AQZF CONTROL TYPE REMOTE
AGLD PERFORMANCE TYPE SEMIAUTOMATIC
ANCQ FULL VOLTAGE RESTORING METHOD CURRENT LIMIT ACCELERATION
ANCN OPERATING VOLTAGE CHARACTERISTIC REDUCED
ANDW LOAD PROTECTION TYPE OVERLOAD AND UNDERVOLTAGE RELEASE
ANCP VOLTAGE REDUCTION METHOD RESISTOR
ABMK OVERALL WIDTH 9.312 INCHES NOMINAL
ZZZY REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS ACUT,ANCY
ABHP OVERALL LENGTH 18.500 INCHES NOMINAL
ACUT DIRECT CURRENT RATING IN AMPS 43.2
ANDX AMBIENT TEMP 50.0 DEG CELSIUS
ABKW OVERALL HEIGHT 25.000 INCHES NOMINAL
ANDE ACTUATOR VOLTAGE 230.0 DC
ZZZT NONDEFINITIVE SPEC/STD DATA 2 SIZE
CBBL FEATURES PROVIDED CIRCUIT PROTECTION FUSE
ANCY HORSEPOWER RATING 1.000
ANPZ INCLOSURE FEATURE DRIPPROOF
AGUE FUSE ACCOMMODATION QUANTITY 1
AKPS DUTY CYCLE CONTINUOUS
AFLW ACTUATION METHOD MAGNETIC
ACYR DC VOLTAGE RATING 230.0 VOLTS NOMINAL
FEAT SPECIAL FEATURES FACILITIES FOR USE OF EXTERNAL SPEED CONTROL RHEOSTAT INCL
ABBB SPEED ADJUSTMENTS SINGLE SPEED
ALGC MOUNTING CONFIGURATION SIX 21/32 IN. DIA MTG HOLES,2 ROWS OF 3 HOLES EA 22 IN. C TO C BETWEEN ROWS AND 7-1/4 IN. C TO C BETWEEN HOLES

Similar Parts

6942ED965-1 , 6942ED9651 , 6110-00-643-0192 , 6110006430192 , 006430192 , MILC2174SIZE2 , 6942ED965-1 , 6942ED965-1MF10HP9104H3964 , 942-1-101M14 , 942-1-101M4 ,