NIIN Output Data
Definition:
AN ITEM CONSISTING OF A PARTIAL TURN AS ONE OR MORE TURNS OF WIRE OR OTHER CONDUCTIVE MATERIAL WHICH CONSTITUTES ONE CONTINUOUS UNTAPPED WINDING. IT MAY BE WOUND OR FORMED IN OTHER THAN A CIRCULAR MANNER AND MAY BE SELF-SUPPORTING, REQUIRING NO COIL FORM. IT IS SPECIFICALLY DESIGNED TO FURNISH INDUCTIVE REACTANCE IN A CIRCUIT CARRYING RADIO FREQUENCY CURRENT RANGING FROM 20 KILOHERTZ (KILOCYCLES) AND ABOVE. IT MAY INCLUDE TUNING DEVICES, INTEGRAL RESISTORS AND CAPACITORS; HOWEVER, EXCLUDES FILTER (AS MODIFIED). THE COIL HAS ONLY TWO ELECTRICAL TERMINALS. FOR ITEMS HAVING TAPPED WINDING OR MORE THAN ONE WINDING - SEE TRANSFORMER, RADIO FREQUENCY. FOR COILS WOUND ON RESISTORS, WHICH ARE DESIGNED TO BE INSERTED IN THE CIRCUIT OF A RADIO FREQUENCY STAGE TO SUPPRESS HIGH FREQUENCY PARASITIC OSCILLATIONS, SEE SUPPRESSOR, PARASITIC.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
506-2991-002 | 13499 | A | 3 | 9 | A | TX | ||
651801-019 | 12436 | A | 5 | 2 | 5 | TX |
CAGE Information
Code | Company |
---|---|
12436 | BAE SYSTEMS NATIONAL SECURITY SOLUTI |
13499 | ROCKWELL COLLINS INC. DBA GOVERNMENT |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CBBL | FEATURES PROVIDED | LEFT HAND WOUND COIL |
ADAR | BODY OUTSIDE DIAMETER | 0.120 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
ACZP | COIL FORM TYPE | SOLID SINGLE COMPONENT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CRLC | FREQUENCY AT WHICH INDUCTANCE AND QUALITY FACTOR APPLIES (NON-CORE) | 60.0 MEGAHERTZ SINGLE COMPONENT SINGLE WINDING |
ACYV | INDUCTANCE RATING | 0.37 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING |
CQPZ | WINDING CONDUCTOR SIZE | 0.00631 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE WINDING |
CRBZ | WINDING OPERATING CURRENT | 31.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE WINDING |
ABHY | TURN QUANTITY | 14 SINGLE COMPONENT SINGLE WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 0.108 SINGLE COMPONENT SINGLE WINDING |
AKNA | INCLOSURE TYPE | OPEN |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
ADAQ | BODY LENGTH | 0.375 INCHES NOMINAL |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING AND WINDING TURNS SINGLE COMPONENT SINGLE WINDING |