NIIN Output Data

NIIN:
NSN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
292-5075G1ISSUE4 49956 A 5 9 5 TX
NE4024A 94315 F 5 9 5 TX
292-5075G1ISSUE4 3B150 A 3 2 5 TX

CAGE Information

Code Company
3B150 RAYTHEON TECHNICAL SERVICES COMPANY
49956 RAYTHEON COMPANY DBA RAYTHEON
94315 NEW ENGLAND TRANSFORMER CO INC

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
CRBZ WINDING OPERATING CURRENT 2.9 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT
CRBZ WINDING OPERATING CURRENT 11.3 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 4TH SECONDARY
THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP
CMLP THREAD QUANTITY PER INCH 20 SINGLE GROUP
ADAU BODY HEIGHT 4.750 INCHES NOMINAL
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
ADAQ BODY LENGTH 6.625 INCHES NOMINAL
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ADAT BODY WIDTH 5.875 INCHES NOMINAL
AKNA INCLOSURE TYPE HERMETICALLY SEALED
AXGY MOUNTING METHOD THREADED STUD SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY
CWJS WINDING OPERATING VOLTAGE 6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT SINGLE PRIMARY
CRBZ WINDING OPERATING CURRENT 1.5 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 5.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CWJS WINDING OPERATING VOLTAGE 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
TTQY TERMINAL TYPE AND QUANTITY 6 SOLDER STUD AND 5 STANDOFF, SOLDER LUG
CWJS WINDING OPERATING VOLTAGE 2.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
AAJD THREAD CLASS (NON-CORE) 2A SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 6.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
CQJX NOMINAL THREAD SIZE 0.250 INCHES SINGLE GROUP
CRBZ WINDING OPERATING CURRENT 5.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY
ACZB FREQUENCY RATING 60.0 HERTZ NOMINAL SINGLE COMPONENT
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 4.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT