Follow Us on Google+

Request A Price Quote:

NIIN Output Data

NIIN:
NSN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
5945007547276 SCY13 A 5 9 9 YP
MS24141-D1 96906 M 2 2 E TX
6042H159 27192 A C 1 5 TX AF
MIL-PRF-6106 81349 M 4 1 4 ZZ
6042H159 81640 A C 1 E TX AF
MIL-R-6106 81349 M 5 9 E TX

CAGE Information

Code Company
27192 DRS POWER & CONTROL TECHNOLOGIES INC
SCY13 E.C.A ETABLISSEMENT CENTRAL DES APPR
96906 MILITARY STANDARDS PROMULGATED BY MI
81349 MILITARY SPECIFICATIONS PROMULGATED
81640 EATON CORPORATION DBA FLUID POWER DI

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKDX WINDING QUANTITY 1
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
AFJN FRAGILITY FACTOR MODERATELY RUGGED
ABHP OVERALL LENGTH 3.640 INCHES MAXIMUM
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 50.0 AMPERES AC LAMP LOAD AND 50.0 AMPERES DC LAMP LOAD
TEST TEST DATA DOCUMENT 81349-MIL-R-6106 SPECIFICATION
APCN COIL QUANTITY 1
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.615 INCHES NOMINAL SINGLE MOUNTING FACILITY
TTQY TERMINAL TYPE AND QUANTITY 4 THREADED STUD ALL FUNCTIONS
CRXH TIME DELAY 0.02 SECONDS MAXIMUM FIXED OPERATE TIME
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 75.0 AMPERES AC MOTOR LOAD AND 100.0 AMPERES DC MOTOR LOAD
CBME CUBIC MEASURE 34.602 CUBIC INCHES
ABMK OVERALL WIDTH 2.925 INCHES MAXIMUM
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 28.0 DC
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 100.0 AMPERES AC RESISTIVE LOAD AND 100.0 AMPERES DC RESISTIVE LOAD
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY
APNQ ARC QUENCHING METHOD AIR
APNA WINDING DC RESISTANCE RATING 64.5 OHMS NOMINAL SINGLE WINDING
ZZZK SPECIFICATION/STANDARD DATA 96906-MS24141 GOVERNMENT STANDARD
AKSL PURPOSE FOR WHICH DESIGNED GENERAL
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
ADZC ENVIRONMENTAL PROTECTION HERMETIC
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.266 INCHES NOMINAL SINGLE MOUNTING FACILITY
APNP DUTY TYPE CONTINUOUS
CQYJ MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY
ADTV CASE MATERIAL METAL
ABKW OVERALL HEIGHT 3.250 INCHES MAXIMUM
CRXH TIME DELAY 0.01 SECONDS MAXIMUM FIXED RELEASE TIME
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 100.0 AMPERES DC INDUCTIVE LOAD
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION

Similar Parts