NIIN Output Data
NIIN:
NSN:
Item Name:
FILTER , BAND PASS
Definition:
AN ITEM DESIGNED TO PASS FREQUENCIES WITHIN A SPECIFIED RANGE (BAND) AND TO SUPPRESS FREQUENCIES OUTSIDE THE RANGE (BAND). EXCLUDES A SINGLE INDUCTANCE, OR A SINGLE CAPACITANCE, OR A SINGLE RESISTANCE. SEE COIL (AS MODIFIED); REACTOR; CAPACITOR (AS MODIFIED); AND RESISTOR (AS MODIFIED).
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
465472-1 | 3B150 | A | 3 | 2 | 1 | TX | ||
465472-1 | 49956 | A | 5 | 9 | 1 | TX |
CAGE Information
Code | Company |
---|---|
3B150 | RAYTHEON TECHNICAL SERVICES COMPANY |
49956 | RAYTHEON COMPANY DBA RAYTHEON |
Federal Supply Class
Title
FILTERS AND NETWORKS
Inclusions:
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AHAS | LOAD IMPEDANCE PER FUNCTION | 75.0 OHMS BLANK |
AFSV | AVERAGE LIFE RATING IN HOURS | 10000.0 |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 3.3 MEGAHERTZ BLANK |
ADAQ | BODY LENGTH | 2.250 INCHES NOMINAL |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | +10.0/+2000.0 |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 75.0 OHMS BLANK |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 1.0 NOMINAL BLANK AND 1.0 NOMINAL BLANK AND 20.0 NOMINAL BLANK AND 20.0 NOMINAL BLANK |
ABKW | OVERALL HEIGHT | 1.030 INCHES MAXIMUM |
CQRG | BODY MATERIAL | METAL |
ADAT | BODY WIDTH | 1.000 INCHES NOMINAL |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 PIN OUTPUT |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 1.5 BLANK |
CRST | BODY SURFACE TREATMENT | TIN |
ADAU | BODY HEIGHT | 0.640 INCHES MAXIMUM |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE BLANK |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 2.00 MEGAHERTZ BLANK AND 4.60 MEGAHERTZ BLANK |
AFGA | OPERATING TEMP RANGE | -20.0/+85.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | ENCASED |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 PIN INPUT |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 2.00 MEGAHERTZ BLANK AND 4.60 MEGAHERTZ BLANK AND 1.30 MEGAHERTZ BLANK AND 6.60 MEGAHERTZ BLANK |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.700 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.950 INCHES NOMINAL |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 PIN GROUND |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 TERMINAL |