NIIN Output Data
Definition:
A VALVE SPECIFICALLY DESIGNED TO AUTOMATICALLY MAINTAIN A PREDETERMINED DISCHARGE FLOW RATE WHICH MAY BE ADJUSTABLE WITHIN A SPECIFIC RANGE. IT IS DESIGNED TO BE USED WITH VARIOUS FLUIDS AND MAY BE PRESET AND/OR ADJUSTABLE. IT MAY BE IN-LINE OR CARTRIDGE (MANIFOLD) DESIGN. EXCLUDES VALVE, REGULATING, FEED WATER; VALVE, REGULATING, FLUID PRESSURE; VALVE, REGULATING, FUEL OIL; VALVE, REGULATING, OIL PRESSURE, AUTOMATIC PILOT; VAVLE, REGULATING, TEMPERATURE; VALVE, ANGLE; AND VALVE, GLOBE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
QSA2-175AXIT | 24785 | H | 3 | 9 | 3 | HD |
CAGE Information
Code | Company |
---|---|
24785 | VICKERS INC |
Federal Supply Class
Title
VALVES, NONPOWERED
Inclusions:
INCLUDES AUTOMATIC NONPOWERED VALVES; GATE, GLOBE, ANGLE, CHECK, AND RELIEF VALVES; COCKS.
Exclusions:
EXCLUDES FIRE HYDRANTS (FSC 4210); SPRINKLER HEADS (FSC 4210); VALVES SPECIFICALLY DESIGNED FOR USE WITH FIRE FIGHTING EQUIPMENT (FSC 4210); PLUMBING EQUIPMENT, AND THE LIKE (FSC 4540).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ACKM | FIRST END CONNECTION TYPE | PLAIN FACE FLANGE |
AEVN | REGULATION TYPE | AUTOMATIC SINGLE STAGE |
ADSY | VALVE DISCHARGE FLOW RATE | 0.0 GALLONS PER MINUTE AND 10.0 GALLONS PER MINUTE |
ACKV | FIRST END FLANGE LENGTH | 3.500 INCHES NOMINAL |
ADQV | FLOW CONTROL DEVICE MATERIAL | STEEL |
ACLA | FIRST END BOLT HOLE DIAMETER | 0.400 INCHES NOMINAL |
FEAT | SPECIAL FEATURES | SUBPLATE MOUNTED |
AEVZ | MAXIMUM INLET PRESSURE RATING | 5000.0 POUNDS PER SQUARE INCH |
AFLN | FIRST END CENTER TO CENTER DISTANCE BETWEEN HOLES ALONG LENGTH | 2.720 INCHES NOMINAL |
ACKW | FIRST END FLANGE WIDTH | 2.625 INCHES NOMINAL |
AAFZ | BODY MATERIAL | IRON, CAST |
ACKT | FIRST END FLANGE SHAPE STYLE | RECTANGULAR (INCLUDES SQUARE) W/ BOLT HOLES |
ACKN | FIRST END STYLE DESIGNATOR | PLAIN |
ACKU | FIRST END FLANGE THICKNESS | ANY ACCEPTABLE |
ACKL | MEDIA FOR WHICH DESIGNED | HYDRAULIC OIL |
AFLS | FIRST END CENTER TO CENTER DISTANCE BETWEEN HOLES ALONG WIDTH | 1.975 INCHES NOMINAL |