Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
3836 | 13483 | A | 3 | 2 | 1 | CX | ||
RYG9175259 | 3B150 | A | 3 | 2 | 5 | CX | ||
9175259 | 18876 | A | 3 | 2 | 1 | CX | ||
RYG9175259 | 49956 | A | 5 | 9 | 5 | CX |
CAGE Information
Code | Company |
---|---|
13483 | PRECISION ELECTRONICS INC. |
3B150 | RAYTHEON TECHNICAL SERVICES COMPANY |
18876 | U S ARMY AVIATION AND MISSILE COMMAN |
49956 | RAYTHEON COMPANY DBA RAYTHEON |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ABKW | OVERALL HEIGHT | 5.375 INCHES NOMINAL |
AAJD | THREAD CLASS (NON-CORE) | 2B SINGLE GROUP |
CMLP | THREAD QUANTITY PER INCH | 24 SINGLE GROUP |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 15 TURRET |
AEHZ | MAXIMUM OPERATING TEMP | 85.0 DEG CELSIUS |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 416.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 5000.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.812 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 1.7 KILOVOLT-AMPERE SINGLE COMPONENT |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 0.333 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY |
AKNA | INCLOSURE TYPE | OPEN |
ABMK | OVERALL WIDTH | 3.500 INCHES NOMINAL |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP |
ABHP | OVERALL LENGTH | 6.875 INCHES NOMINAL |