NIIN Output Data
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
RNF-100-1/4-RD-SP | 06090 | A | 5 | 9 | 4 | CX | ||
RNF-100 TYPE1 1/4IN RED | 06090 | A | 5 | 9 | 4 | CX | ||
M23053/5-106-2 | 81349 | M | 5 | 9 | 4 | CX | ||
RT8761-4IDRED | 06090 | A | C | 1 | 9 | TU | ||
ST-221-1/4IN RED | 56352 | A | 5 | 1 | E | CX | ||
94-0073 | 19397 | A | 5 | 2 | A | CX | ||
59122-06 | 09795 | A | 3 | 2 | 4 | CX | ||
PENNTUBE V FLEXIBLE 1/4IN RED | 09795 | A | 5 | 1 | 5 | CX | ||
FIT-221-1/4RED | 92194 | Y | 3 | 2 | 4 | ZZ | ||
RNF100 1-4RED | 06090 | A | 5 | 9 | 4 | CX | ||
MMS-809-2-T1/4 | 76301 | A | E | 8 | E | CX | ||
2526070-34 | 10001 | A | 3 | 2 | X | XX | ||
AMS-DTL-23053/5 | 81343 | A | 5 | 1 | E | ZZ | ||
RNF-100-122-2 | 06090 | A | E | 8 | E | CX | ||
RNF100-1-4REDL0NGUEUR4FEET | F0286 | A | 5 | 2 | 4 | ZF | ||
FP301-1 1/4IN RED | 20999 | A | 3 | 2 | 5 | CX | ||
M23053/5-106-2 | 81343 | A | 3 | 2 | E | ZZ | ||
R2479P66 | 23991 | A | 5 | 9 | A | CX | ||
45-033344-44 | 26916 | A | 5 | 2 | 5 | ZZ | ||
204745 | F5350 | A | 5 | 2 | 1 | ZF | ||
RNF100-1-4REDL0NGUEUR4FEET | F6220 | R | 5 | 9 | 4 | ZF | ||
344636-6RED | 49956 | A | 5 | 9 | 3 | CX | ||
PO135 1/4IN RED | 03890 | A | 3 | 2 | 5 | CX | ||
344636-6RED | 3B150 | A | 3 | 2 | 3 | CX | ||
Y00037-106 | 12436 | A | 5 | 9 | A | CX | ||
1130389G28 | 31550 | A | 5 | 1 | A | CX | ||
7956686-32 | 90536 | A | C | 1 | 5 | ZZ | AC | |
45-033344-44 | 15280 | R | 5 | 9 | 1 | CX | ||
RNF100-1-4RED | 06090 | A | 3 | 2 | 4 | 9Z | ||
GMS5-20-16-2 | 25500 | A | 5 | 1 | A | CX | ||
MIL-I-23053/5 | 81349 | M | 5 | 9 | 4 | CX | ||
224845-206 | 81413 | A | 5 | 1 | A | CX | ||
RT-876 1/4IDRED | 06090 | A | 5 | 2 | 5 | 9Z | ||
BATCH63A55-2 | 81205 | A | 5 | 1 | 5 | CX | ||
065-001756-034 | 26916 | A | 5 | 1 | E | CX |
CAGE Information
Code | Company |
---|---|
03890 | MARKEL CORP. |
06090 | TYCO ELECTRONICS CORPORATION DIV RAY |
81349 | MILITARY SPECIFICATIONS PROMULGATED |
56352 | MANHATTAN/CDT COLE-FLEX |
19397 | BAE SYSTEMS INFORMATION AND ELECTRON |
09795 | SAINT-GOBAIN PERFORMANCE PLASTICS CO |
92194 | ALPHA WIRE CORP |
76301 | BOEING COMPANY THE DBA BOEING |
10001 | NAVAIR AND NAVSEA MANAGED ORIGINAL D |
81343 | SOCIETY OF AUTOMOTIVE ENGINEERS INC |
F0286 | TYCO ELECTRONICS FRANCE SAS |
20999 | 3M CO ADMININISTRATIVE ELECTRONIC & |
23991 | LOCKHEED MARTIN CORPORATION DIV LOCK |
26916 | NORTHROP GRUMMAN SYSTEMS CORPORATION |
F5350 | DGA/DSA/UM ESIO |
F6220 | RAYCHEM SA |
49956 | RAYTHEON COMPANY DBA RAYTHEON |
3B150 | RAYTHEON TECHNICAL SERVICES COMPANY |
12436 | BAE SYSTEMS NATIONAL SECURITY SOLUTI |
31550 | ITT CORPORATION DBA ITT COMMUNICATIO |
90536 | LOCKHEED MARTIN CORPORATION DBA LOCK |
15280 | NORTHROP GRUMMAN SYSTEMS CORPORATION |
25500 | LOCKHEED MARTIN CORPORATION DBA LOCK |
81413 | BAE SYSTEMS INFORMATION AND ELECTRON |
81205 | THE BOEING COMPANY DBA BOEING DIV DE |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
STYL | STYLE DESIGNATOR | SHRINKABLE |
FLEX | FLEXIBILITY | FLEXIBLE |
ABHP | OVERALL LENGTH | ANY ACCEPTABLE |
AGAU | HEAT SHRINKAGE RATING IN PERCENT | 50.0 |
MATL | MATERIAL | PLASTIC, POLYOLEFIN, MIL-I-23053/5, CLASS 1 |
ADZC | ENVIRONMENTAL PROTECTION | MILDEW RESISTANT AND FLAME RESISTANT AND CORROSION RESISTANT AND WATER RESISTANT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJH | TEMP RATING | -55.0 DEG CELSIUS AND 135.0 DEG CELSIUS |
CQBC | MINIMUM TENSILE STRENGTH | 1500 POUNDS PER SQUARE INCH |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 500.0 VOLTS PER MIL /0.001 INCH/ |
AFZN | RECOVERED WALL THICKNESS | 0.022 INCHES MINIMUM AND 0.028 INCHES MAXIMUM |
AFZL | EXPANDED INSIDE DIAMETER | 0.250 INCHES MINIMUM |
HUES | COLOR | RED |
AFZM | RECOVERED INSIDE DIAMETER | 0.125 INCHES MAXIMUM |