NIIN Output Data
NIIN:
NSN:
Item Name:
PUMP , SUBMERGED , AIRCRAFT
Definition:
A COMPLETELY INCLOSED MACHINE CONSISTING OF A POSITIVE OR NONPOSITIVE DISPLACEMENT PUMP WITH A DRIVING MOTOR USED TO TRANSMIT OR TRANSFER FLUID FROM AN AIRCRAFT TANK TO AN ENGINE DRIVEN PUMP OR TO ANOTHER TANK. IT IS DESIGNED TO BE PARTIALLY OR COMPLETELY SUBMERGED IN THE FLUID IT IS INTENDED TO PUMP.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
32-58020-7 | 76301 | A | 7 | 2 | 2 | SE | ||
60-057C | 81982 | A | 3 | 2 | 2 | SE |
CAGE Information
Code | Company |
---|---|
76301 | BOEING COMPANY THE DBA BOEING |
81982 | HYDRO-AIRE INC. |
Federal Supply Class
Title
ENGINE FUEL SYSTEM COMPONENTS, A
Inclusions:
INCLUDES CARBURETORS; FUEL PUMPS; ENGINE FUEL FILTERS; FUEL CONTROLS, JET ENGINE; FUEL PRIMERS; WATER INJECTION CONTROLS AND VALVES; FUEL VALVES FUEL FLOW REGULATORS; COMPONENTS OF SMOKE ABATEMENT SYSTEMS.
Exclusions:
EXCLUDES AIRCRAFT FUEL TANKS (FSC 1560); IN-FLIGHT REFUELING SYSTEM FUEL COMPONENTS (FSC 1680). FUEL SYSTEM COMPONENTS NOT SPECIFICALLY DESIGNED FOR USE WITH AIRCRAFT ENGINES OR MISSILE PRIME-MOVERS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
TEXT | GENERAL CHARACTERISTICS ITEM DESCRIPTION | DESIGNED FOR PARTIALLY SUBMERGED OPERATION,NON POSITIVE DISPLACEMENT,2 IMPELLERS DOUBLE ENDED TYPE,115/200V AC 400 CPS 3 PH,36000 PHR AT 20 PSI W/JP4 OR JP5 FUEL,15.960 IN. LG 11.880 IN. W 7.880 IN. H O/A DIM.,12 MTG HOLES 0.266 IN. DIA EVENLY SPACED AROUND A 11.880 IN. BY 7.880 IN. OVAL MTG FLANGE,7 CONTACT MS TYPE ELECTRICAL CONNECTOR MTD ON HOUSING,EXTERNAL DISCHARGE BOSS FOR 2.750 IN. ID CONNECTION |