NIIN Output Data
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
2036772PC1 | 10001 | A | 3 | 2 | 1 | CX |
CAGE Information
Code | Company |
---|---|
10001 | NAVAIR AND NAVSEA MANAGED ORIGINAL D |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
MATT | MATERIAL | PLASTIC MELAMINE BOARD AND SILICA BOARD |
ABGS | BASE THICKNESS | 0.250 INCHES |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.287 INCHES |
CQCZ | TERMINAL CONNECTING LINK QUANTITY | 42 SINGLE |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
AMPS | CURRENT RATING IN AMPS | 15.0 |
CWLN | TERMINAL DESIGN | LINKED NONFEEDTHRU |
AAMA | MOUNTING HOLE DIAMETER | 0.160 INCHES |
ABGQ | BOARD OVERALL HEIGHT | 0.406 INCHES |
ABCS | TERMINAL ROW QUANTITY | 2 |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-14,TYPE MME MIL SPEC SINGLE MATERIAL RESPONSE BOARD |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
ABGN | BOARD OVERALL LENGTH | 8.531 INCHES |
CSCR | TERMINAL CONNECTING LINK TYPE | 1 SINGLE |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.312 INCHES |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 42 SINGLE |
CRNL | NONFEEDTHRU TERMINAL TYPE | 857 SINGLE |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.375 INCHES |
ABGP | BOARD OVERALL WIDTH | 0.875 INCHES |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.406 INCHES |
ABCX | BOARD CONSTRUCTION | HOLLOW CONSTRUCTION WITHOUT INSULATED STRIP |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | QQ-N-290,CL 2 FED SPEC SINGLE TREATMENT RESPONSE TERMINALS |
SFTT | SURFACE TREATMENT | NICKEL TERMINALS |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 8.249 INCHES |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.312 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.141 INCHES |
AAQL | BODY STYLE | BARRIER TYPE |