Follow Us on Google+

Request A Price Quote:

NIIN Output Data

NIIN:
NSN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
2780 13483 A 5 2 5 TX
RYG9175618 3B150 A 5 2 5 TX
9175618 18876 A 3 2 1 TX
RYG9175618 49956 A 5 9 5 TX
43173 73386 A 5 2 5 TX

CAGE Information

Code Company
13483 PRECISION ELECTRONICS INC.
3B150 RAYTHEON TECHNICAL SERVICES COMPANY
18876 U S ARMY AVIATION AND MISSILE COMMAN
49956 RAYTHEON COMPANY DBA RAYTHEON
73386 FREED TRANSFORMER COMPANY

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT 3RD SECONDARY
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
ADAT BODY WIDTH 3.532 INCHES NOMINAL
ADAU BODY HEIGHT 3.500 INCHES NOMINAL
AAJD THREAD CLASS (NON-CORE) 2B SINGLE GROUP
TTQY TERMINAL TYPE AND QUANTITY 11 TURRET
AKNA INCLOSURE TYPE FULLY INCLOSED
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT
THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP
CRBZ WINDING OPERATING CURRENT 5.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY
CRBZ WINDING OPERATING CURRENT 15.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AARG RELIABILITY INDICATOR NOT ESTABLISHED
AXGY MOUNTING METHOD THREADED HOLE SINGLE GROUP
CQJX NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
CWJS WINDING OPERATING VOLTAGE 6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT 1ST SECONDARY
ADAQ BODY LENGTH 3.532 INCHES NOMINAL
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 240.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
CMLP THREAD QUANTITY PER INCH 32 SINGLE GROUP
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT 2ND SECONDARY
CRBZ WINDING OPERATING CURRENT 70.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY
CWJS WINDING OPERATING VOLTAGE 6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY

Similar Parts