Follow Us on Google+

Request A Price Quote:

NIIN Output Data

NIIN:
NSN:
Item Name:
RELAY , THERMAL

Definition:

A RELAY SWITCH WHICH IS ACTUATED BY THE EFFECT OF INTERNAL HEAT GENERATED BY THE CURRENT IN ITS ENERGIZING CIRCUIT. FOR ITEMS ACTUATED BY AMBIENT, RATHER THAN INTERNAL TEMPERATURE CHANGES, SEE SWITCH, THERMOSTATIC.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
25850-01 92739 R 5 9 5 TX
GT-4473 93929 A 5 2 A TX
GT-2532 93929 A 5 2 5 TX
GT-2583 93929 A 5 2 5 TX
271MS188P001 49956 A 5 9 1 TX
720125-1REVD 80249 A 5 9 1 HH
GT-4368 93929 A 5 2 5 TX
RF-30-N0-115 93929 A 5 2 5 TX
271MS188P001 3B150 A 3 2 1 TX
RF-30-N0-115-30SEC 93929 A 5 2 5 TX
380C17092-2 94990 R 5 9 5 TX
380C17092-2 1VPW8 A 5 2 5 ZZ

CAGE Information

Code Company
1VPW8 GENERAL DYNAMICS C4 SYSTEMS INC.
92739 AMPEX SYSTEMS CORP
93929 SPX CORPORATION DBA RADIODETECTION
49956 RAYTHEON COMPANY DBA RAYTHEON
80249 BAE SYSTEMS INFORMATION AND ELECTRON
3B150 RAYTHEON TECHNICAL SERVICES COMPANY
94990 MOTOROLA INC. DBA INTEGRATED INFORMA

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
ABKW OVERALL HEIGHT 1.000 INCHES NOMINAL
ABHP OVERALL LENGTH 2.406 INCHES MAXIMUM
CYCW DELAY TIME IN SECONDS 30.0 ADJUSTABLE OPERATE NOMINAL
CYCV HEATER POWER RATING IN WATTS 4.0
ABMK OVERALL WIDTH 1.380 INCHES NOMINAL
APFR CONTACT ARRANGEMENT SINGLE POLE, SINGLE THROW, NORMALLY OPEN
CYCU HEATER VOLTAGE RATING IN VOLTS 115.0
CYCT CONTACT MAXIMUM CURRENT RATING IN AMPS 3.0 AC
CYCS CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE

Similar Parts

380C17092-2 , 380C170922 , 5945-00-811-6079 , 5945008116079 , 008116079 , 25850-01 , GT-4473 , GT-2532 , GT-2583 , 271MS188P001 , 720125-1REVD , GT-4368 , RF-30-N0-115 , 271MS188P001 , RF-30-N0-115-30SEC , 380C17092-2 , 380C17092-2 ,